· pdf filepiperonal. if the substance is a liquid, the appearance of an orange color...
TRANSCRIPT
Acid
Dilu
tion 6 7With
squeeze chamber 2 until capsule breaks.
, thumb and forefinger Gently shake test unit for 2-3 seconds.
Wait 5 minutes.
Dis
posa
l
The test kit is now safe to dispose of in the trash.
Aci
d D
ilutio
n 8 9Withsqueeze chamber 3 until capsule breaks.
, thumb and forefinger Gently shake test unit for 2-3 seconds.
DentaIWorld Leader inForensic Products
All results are presumptive. If necessary, further confirmatory testing by a competent drug testing lab may provide additional identification and quantification using gas chromatography/mass spectrometry analysis.
99% accurate presumptive field screening when used correctly.
Manufactured by IDenta Corp.www.identa-corp.com • +972-2-5872220
• Patented Technology Made in Israel
The test window will warm up. This is normal.
The test window will warm up.This is normal.
As a precaution, gloves and eye protection should be worn when handling drug substances and using test units.Do not puncture any part of unit. Do not remove probe once locked into unit.
In the unlikely event of a spill, rinse affected area thoroughly with water.Keep out of reach of children.
G e n t l y shake test unit for 2-3 seconds.
4With
, squeeze chamber 1 until capsule breaks.
thumb and forefinger 5
Iden
tific
atio
n
If no color develops, MDMA/Amphetamine precursors are not present.
Proceed to Acid Dilution (steps 6-9),regardless of whether or not a color appeared.
The appearance of a red-brown color indicates the presence of 3,4-Methyleneedioxyphenyl-2 propanone (PMK, MDP2P).
The appearance of an intense yellow color indicates the presence of Piperonal.
If the substance is a liquid, the appearance of an orange color indicates the presence of Safrole. * Color may turn to violet after 10-15 minutes.
If the substance is a solid, the appearance of an orange color indicates the presence of 1-phenyl-2-propaneone (BMK).
Resu
lts
Powder21
Test
Pre
para
tion
Sample suspected substance.
T o u c h a d h e s i v e Smart-Tip™ to sample.
Liquid
R e m o v e t h e S m a r t - Ti p ™ probe from test unit.
Place the absorbent paper of Smart-Tip™ probe into liquid. Make sure paper is wet.
Lock Smart-Tip™ probe into test unit. Press firmly.
3
Test
Pre
para
tion
FlexPins
Lock Smart-Tip™ probe into test unit. Press firmly.
3
Test
Pre
para
tion
FlexPins
Do not continue
unless probe is locked below the Flex Pins and cannot be removed from the test unit.
A click sound will indicate the probe is
locked.
10-13
READ BEFORE USE
IDenta MDMA - Amphetamine PrecursorsSubstance
Procedure Card for IDT 0270-10DRUG PRECURSORS TEST KIT