新彩页模板 - ucelecza.com · bc-3200 bc-3200 auto hematology ... setup, service , calibration,...
TRANSCRIPT
Auto Hematology AnalyzerBC-3200
BC-3200Auto Hematology Analyzer
Closed tube sampling
Sampling with 4 position tube holder
Micro sampling of 13 µL
3-part di�erential,19 parameters + 3 histograms
Up to 60 samples per hour
Large color LCD display
Data storage of 35 , 000 samples with histogram
Flexible and Easy To UseFully automatic analysis cycle
Intelligent alarm to avoid wrong tube
Automatic internal and external needle cleaning
High Reliability and SafetySampling on closed tube to avoid biohazard
Automatic protection when chamber door is open
Cyanide-free reagent to protect environment
Total Solution for QC and CalibrationComprehensive QC programs including L - J , X , X-R and X-B analysis
Up to 9 QC �le-31 runs / �le
Fully automatic calibration
Unique calibration program with fresh blood
Powerful Customizable Software DesignHuge storage of 35 , 000 patient results with histogram
Convenient patient data review
Programmable multi-format printout
Fully automatic daily maintenance program
BC-3200Auto Hematology Analyzer
P/N:FRA-BC3200-210285x4-20100203
Technical Speci�cations:
DisplayLarge Color LCD display Resolution : 800 x 600
Alerts 45 sets of alert message
Menu Count , Sample Mode , Review , Quality Control , Setup, Service , Calibration, Help , Shutdown
CarryoverWBC, RBC, HGB < 0 . 5 % , PLT < 1 %
Input/OutputRS232 x 2 , 1 Parallel printer ( optional ) , 1 bar code scanner ( optional ) , 1 keyboard interface
Printout Thermal recorder , 50mm wide paper , multitude of printout formats , printer optional
Operating Environment Temperature:15°C-30°CHumidity : 30 % ~85 %
Power Requirement AC 100-240V, 50 / 60Hz
Dimension 457mm (H) x 391mm (W) x 425mm (D)
Weight 25 Kg
Parameters WBC , Lymph # , Mid # , Gran # , Lymph % , Mid % , Gran % , RBC , HGB , HCT , MCV , MCH , MCHC , RDW-CV , RDW-SD, PLT , MPV , PDW , PCT and Histogram for WBC , RBC , PLT
Principles Electrical resistance for counting and Cyanide free method for hemoglobin
PerformanceParameter Linearity Range Precision ( CV % )WBC ( 109 / L ) 0.3~99.9 2.5(7.0~15.0)RBC ( 1012 / L ) 0.20~8.0 2 (3.5~6.0)HGB ( g / L ) 10~250 1.5(110-180)MCV(FL) 0.5(80.0~110.0)PLT ( 109 / L ) 10~99.9 5(150~500)
Sample VolumePrediluted 20 µLWhole Blood 13 µL
Sample processingOn closed tube with 4 position tube holder ( QC , 1.5mL , 3mL , 5mL )
Aperture Diameter WBC 100 µmRBC/PLT 70 µm
Dilution Rations Whole Blood Capillary BloodWBC 1:308 1:546RBC/PLT 1:44872 1:45827
ThroughPut60 samples per hour
Mindray Building, Keji 12th Road South, High-tech Industrial Park,Nanshan, Shenzhen 518057, P.R. China
Tel: +86 755 26582888 Fax: +86 755 26582680E-mail: [email protected] Website: www.mindray.com
Mindray is listed on the NYSE under the symbol”MR”