atek defense systems, llc 225 w. arrowhead

81
National Technical Systems, Inc. Main: 316-832-1600 7447 W. 33 rd Street N., Wichita, KS 67205 Email: [email protected] www.nts.com June 27, 2017 Mr. Dean Casutt ATEK Defense Systems, LLC 225 W. Arrowhead Trail Rd Spanish Fork, UT 84660 US Dear Mr. Casutt: In accordance with your instructions, National Technical Systems, Inc. conducted Ballistic Resistance Testing of Body Armor submitted by Survival Armor Test ID # MC02887 which were received June 10 th –June13 th , 2017. Testing was not witnessed by a representative of the manufacturer. Ballistic resistance testing was authorized by the National Law Enforcement and Corrections Technology Center (NLECTC) Body Armor Compliance Testing Program (BA CTP), a program of the National Institute of Justice (NIJ) and was conducted in accordance with the requirements of: NIJ Standard-0101.06, Ballistic Resistance Testing of Body Armor, July 2008 in accordance with NIJ BA CTP Administrative Clarification CTP 2015: 03, May 18, 2015, including all clarifications, verbal and written, authorized by the NIJ BA CTP prior to the date of testing. The results of this test are used by the CTP to determine compliance of armor intended for use by Law Enforcement Officers. National Technical Systems, Inc. is not empowered to issue or deny compliance status; however, the attached data indicates that this sampling of Test ID # MC02887 did satisfy the ballistic requirements of NIJ Standard-0101.06 for Threat Level IIIA, a prerequisite to issuance of a compliance status by the CTP. Ballistic test results have been recorded on the most current version of the Compliance Test Report (CTR) provided by the CTP. As required, two complete test samples (four panels) along with the CTR are being forwarded to the CTP. The prospective model designation for this armor is: NPK-3A-1 Please refer to NTS Report Number ATEK17-002-IIIA-M for test details. Sincerely, Jake Crawford Range Operations Manager

Upload: others

Post on 16-Mar-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

National Technical Systems, Inc. Main: 316-832-1600 7447 W. 33rd Street N., Wichita, KS 67205 Email: [email protected]

www.nts.com June 27, 2017 Mr. Dean Casutt ATEK Defense Systems, LLC 225 W. Arrowhead Trail Rd Spanish Fork, UT 84660 US Dear Mr. Casutt: In accordance with your instructions, National Technical Systems, Inc. conducted Ballistic Resistance Testing of Body Armor submitted by Survival Armor Test ID # MC02887 which were received June 10th –June13th, 2017. Testing was not witnessed by a representative of the manufacturer. Ballistic resistance testing was authorized by the National Law Enforcement and Corrections Technology Center (NLECTC) Body Armor Compliance Testing Program (BA CTP), a program of the National Institute of Justice (NIJ) and was conducted in accordance with the requirements of: NIJ Standard-0101.06, Ballistic Resistance Testing of Body Armor, July 2008 in accordance with NIJ BA CTP Administrative Clarification CTP 2015: 03, May 18, 2015, including all clarifications, verbal and written, authorized by the NIJ BA CTP prior to the date of testing. The results of this test are used by the CTP to determine compliance of armor intended for use by Law Enforcement Officers. National Technical Systems, Inc. is not empowered to issue or deny compliance status; however, the attached data indicates that this sampling of Test ID # MC02887 did satisfy the ballistic requirements of NIJ Standard-0101.06 for Threat Level IIIA, a prerequisite to issuance of a compliance status by the CTP. Ballistic test results have been recorded on the most current version of the Compliance Test Report (CTR) provided by the CTP. As required, two complete test samples (four panels) along with the CTR are being forwarded to the CTP. The prospective model designation for this armor is: NPK-3A-1 Please refer to NTS Report Number ATEK17-002-IIIA-M for test details. Sincerely,

Jake Crawford Range Operations Manager

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Identification Number:Issue/Revision Number:

Report Date:

Authorized Signatory: Function/Position:

Signature:

Date:

Test Laboratory Name:Address:

Customer:

ATEK17-002-IIIA-MInitial Issue06/26/17

National Technical Systems-Wichita Division

NIJ BA CTP Compliance Test Report

200818-0NVLAP Lab Code

7447 West 33rd Street NorthWichita, KS 67205

Address:

Conditioning Laboratory Name:

7447 West 33rd Street NorthWichita, KS 67205

ATEK Defense Systems, LLC.

U.S.A.

Spanish Fork, UT 84660

Range Operations Manager

225 W. Arrowhead Trail Rd.

U.S.A.

National Technical Systems-Wichita Division

Jake Crawford

NPK-3A-1

Reproduction of this test report is prohibited except in full.

This test report may not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the Federal Government.

Test results relate only to the items tested.

Address:

Prospective Model Designation:

This test report and the results herein are to be used solely for the purpose of determining compliance to the NIJ 0101.06 Body Armor Standard. The test data should not be used to compare the relative performance characteristics between different models of body armor.

U.S.A.

Report Cover sheetPage 1 of 69NIJ CTR 2-25

6/26/2017

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

NVLAP Lab Code: Test Laboratory Name:Report Identification Number:

Issue / Revision Number:

Test Start Date: 06/12/17 Report Date: 06/26/17 Observors:End Date: 06/22/17

RANGE INFORMATION:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Velocity Measurement Units: Velocity 2: 4.085 ft. 1.245 m Chronographs will report the time of flight.

ARMOR DESCRIPTION: Data should be entered in µs (10 -̂6 s).

Manufacturer:

Date Rec'd: Test ID: NIJ Armor Type: 3AStyle:

SHOT-TO-EDGE REQUIREMENTS: Yes (Yes/No)

Threat 1: 2.0 - 2.75 Inches Yes (Yes/No)Threat 2: 3.0 - 3.75 Inches Labels meet the requirements of 4.1.5.3

ARMOR CONSTRUCTION:Panel A Panel B

Front Closure (Y/N): No Single Panel Design (Y/N): No

Armor Test Configuration: Planar Armor Test Configuration: Planar

Number of Layers: Number of Layers:

Individual Layer Description:

Description of Stitching:

Remarks andRevision History:

Initial Issue

No Witness Present

ATEK17-002-IIIA-M

Information shall represent the back panel in two-panels designs. Completetion not nessesary for single-panel designs.

Labels legible and adhered after wear tests?

Labels legible and adhered after conditioning protocol:

MC02887

Compliance Test Report revision 0 (2015-05-22) / MS Excel version 14.0 / Operating System version Windows (32-bit) NT 6.01

National Technical Systems-Wichita Division200818-0

Male/Side Opening06/10/17

ATEK Defense Systems, LLC.

COMPLIANCE TESTING INFORMATION

time

25 25

Project Manager: Nguyen Range Technician(s) New P-BFS: Zerger New BL: Wilson/Elston/Nold Conditioned P-BFS/BL: Nguyen/Wilson/Nold

Panels A&B_Size C-1_Two-Panel Design:C-1:Layers 1-25: (1) 3.0" and (1) 4.0" diagonal / parallel bar tack at each of the (4) corners *(Top Left, Top Right, Bottom Left, Bottom Right)

Panels A&B_Size C-5_Two-Panel Design:C-5:Layers 1-25: (1) 4.0" and (1) 5.0" diagonal / parallel bar tack at each of the (6) corners *(Top Left, Top Right, Bottom Left, Bottom Right, Top Left Wing, Top Right Wing)

Panels A&B_Size C-5_Two-Panel Design:Layer 1: Coated flex woven aramid fiber (24x24)

Layers 2-8: Smooth flex polyetheylene film

Layers 9-11: Coated flex woven aramid fiber (24x24)

Layers 12-19: Smooth flex polyetheylene film

Layers 20-25: Coated flex woven aramid fiber (24x24)

Information shall represent the front panel in two-panels designs, and all panels in single-panel designs.

Panels A&B_Size C-1_Two-Panel Design:Layer 1: Coated flex woven aramid fiber (24x24)

Layers 2-8: Smooth flex polyetheylene film

Layers 9-11: Coated flex woven aramid fiber (24x24)

Layers 12-19: Smooth flex polyetheylene film

Layers 20-25: Coated flex woven aramid fiber (24x24)

Laboratory and ArmorPage 2 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Use this space to enter any necessary supplemental information

Test Remarks / Notes / Revision History:1) Initial Isssue2) Photos taken as needed for the following: a. Pre and Post Test of New and Conditioned P-BFS (Both Sizes for Threat 1 & Threat 2) b. 12-Shot V50 Shot Pattern Templatec. Failures (if applicable)

Strapping Method (Section 7.7.2.1):(a) Default Strapping Method: Two vertical and three horizontal strapsC-1 Panels A&B : (Figure A.) Standard Strapping Arrangement for Smaller SamplesC-5 Panels A&B: (Figure B.) Standard Strapping Arrangement for Larger Sample with Fixture Extensions

Flexible Armor Conditioning Protocol / Ballistic Testing Timeline:Male Armor Model of a Two-Panel Design IAW CTP AC 2015:03:1) 06/10/17 - 06/13/17: (44) C-5 panels and (12) C-1 panels for New, Threat 2 P-BFS Testing were received and allowed to acclimate for 24 hours at pretest conditions prior to exposure to Section 5 conditioning protocol and ballistic testing.2) 06/11/17: (12) C-5 panels and (4) C-1 panels entered chamber for 10 day temperature, humidity and mechanical wear (tumbling) exposure IAW Section 5. Flexible Armor Conditioning Protocol3) 06/12/17: New, Threat 1 and Threat 2 P-BFS Testing performed4) 06/15/17 - 06/21/17: New Threat 1 and Threat 2 BL Testing performed5) 06/21/17: (12) C-5 and (4) C-1 panels removed from chamber and allowed to return to pretest conditions for a minimum of 12 hours prior to ballistic testing6) 06/22/17: Conditioned Threat 1 and Threat 2 P-BFS and BL Testing performed7) 06/25/17: Sample 09, Panel B (S/N: 054) used to perform Label Permanency and Durability Test IAW Section 4.1.5.3

CTR Pages Omitted:Page 17: HandloadsPages 66-67: Penetration and BFS Firing Data - New Armor - SparePages 68-69: Ballistic Limit Firing Data - New Armor - Spare

Samples Sent to CTP:1) (Shot/C-1 Sample with highest BFS) Sample 07, Panel A (S/N: 006) and Panel B (S/N: 007)2) (Unshot/New Spare C-5 Sample) Sample 10, Panel A (S/N: 055) and Panel B (S/N: 056)*All tested and untested panels not listed above will be held at NTS until released by the CTP

Additional InformationPage 3 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

NVLAP Lab Code: Test Laboratory Name:Report Identification Number:

Issue / Revision Number:

Manufacturer: Test ID: NIJ Type:

Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel BSize: C-5 C-5 C-5 C-5 C-1 C-1 C-1 C-1 C-5 C-5 C-5 C-5 C-1 C-1 C-1 C-1 C-5 C-5 C-5 C-5

Panel Serial Number: 024 025 022 030 003 002 001 011 031 032 021 023 006 007 008 012 047 054 055 056Plate Serial Number: N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Lot Number: 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120Gross Weight (lb.): 4.70 4.81 4.72 4.67 1.49 1.52 1.50 1.51 4.57 4.71 4.72 4.56 1.47 1.50 1.47 1.48 4.74 4.58 4.60 4.60

Test Condition: Wet Wet Wet Wet Wet Wet Wet Wet Wet Wet Wet Wet Wet Wet Wet WetThreat Ammunition: .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag

Bullet (grain/type): 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHPTest Velocity (ft/s): 1470 1470 1470 1470 1470 1470 1470 1470 1430 1430 1430 1430 1430 1430 1430 1430

Angle at Location #4: 30 45 45 30 30 45 45 30 30 45 45 30 30 45 45 30

Bullet Manufacturer: Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer SpeerBullet Lot/Product Number: 4362 4362 4362 4362 4362 4362 4362 4362 4453 4453 4453 4453 4453 4453 4453 4453

Test Barrel Manufacturer: WC040836 WC040836 WC040836 WC040836 WC040836 WC040836 WC040836 WC040836 WC040850 WC040850 WC040850 WC040850 WC040850 WC040850 WC040850 WC040850 Test Barrel Length (in): 4 4 4 4 4 4 4 4 10 10 10 10 10 10 10 10

Manufacturer: Test ID: NIJ Type:

Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel BSize: C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5

Panel Serial Number: 033 034 035 053 037 038 039 040 041 042 043 044 045 046 036 048 049 050 051 052Plate Serial Number: N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Lot Number: 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120Gross Weight (lb.): 4.67 4.70 4.76 4.57 4.76 4.73 4.65 4.73 4.77 4.71 4.72 4.71 4.69 4.76 4.71 4.72 4.63 4.74 4.70 4.78

Test Condition: Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry DryThreat Ammunition: .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .357 SIG .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag .44 Mag

Bullet (grain/type): 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 125/FMJ 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHP 240/SJHPTest Velocity (ft/s): 1470 1470 1470 1470 1470 1470 1470 1470 1470 1470 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430

Shots on Panel: 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12

Bullet Manufacturer: Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer SpeerBullet Lot/Product Number: 4362 4362 4362 4362 4362 4362 4362 4362 4362 4362 4453 4453 4453 4453 4453 4453 4453 4453 4453 4453

Test Barrel Manufacturer: WC040851 WC040851 WC040851 WC040851 WC040851 WC040851 WC040851 WC040851 WC040851 WC040851 WC050850 WC050850 WC050850 WC050850 WC050850 WC050850 WC050850 WC050850 WC050850 WC050850 Test Barrel Length (in): 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Manufacturer: Test ID: NIJ Type:

Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel B Panel A Panel BSize: C-5 C-5 C-1 C-1 C-5 C-5 C-1 C-1 C-5 C-5 C-5 C-5 C-5 C-5 C-5 C-5

Panel Serial Number: 020 019 004 005 026 015 009 010 027 028 013 014 016 018 017 029Plate Serial Number: N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Lot Number: 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120 5301700120Gross Weight (lb.): 4.78 4.71 1.51 1.51 4.66 4.82 1.51 1.50 4.71 4.66 4.74 4.72 4.72 4.72 4.58 4.79

Test Condition: Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry DryThreat Ammunition: .357 SIG .357 SIG .357 SIG .357 SIG .44 Mag .44 Mag .44 Mag .44 Mag .357 SIG .357 SIG .44 Mag .44 Mag

Bullet (grain/type): 125/FMJ 125/FMJ 125/FMJ 125/FMJ 240/SJHP 240/SJHP 240/SJHP 240/SJHP 125/FMJ 125/FMJ 240/SJHP 240/SJHPTest Velocity (ft/s): 1410 1410 1410 1410 1340 1340 1340 1340 1410 1410 1340 1340

Angle at Loc #4/Shots on Panel: 30 45 45 30 30 45 45 30 12 12 12 12

Bullet Manufacturer: Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer Speer SpeerBullet Lot/Product Number: 4362 4362 4362 4362 4453 4453 4453 4453 4362 4362 4453 4453

Test Barrel Manufacturer: WC040836 WC040836 WC040836 WC040836 WC040850 WC040850 WC040850 WC040850 WC040851 WC040851 WC050850 WC050850 Test Barrel Length (in): 4 4 4 4 10 10 10 10 10 10 10 10

Sample 15 Sample 16 Sample 17 Sample 18 Sample 20

3A

Sample 28

Sample 19

TEST DESCRIPTION

ATEK Defense Systems, LLC.

Sample 6 Sample 7

MC02887

Sample 14

Penetration-Backface Signature (P-BFS) Test Samples Spare SamplesSample 24

SAMPLE DESCRIPTION

SAMPLE DESCRIPTION

ATEK Defense Systems, LLC.

SAMPLE DESCRIPTIONSample 11

ATEK Defense Systems, LLC.

TEST DESCRIPTION

THREAT DESCRIPTION

Baseline Ballistic Limit - Threat 1

Sample 25

Sample 4 Sample 5Penetration-Backface Signature (P-BFS) Test Samples Spare Samples

Sample 8

Sample Information and Description

3A

Sample 9 Sample 10

Armors in "As-New" Condition

Sample 12Baseline Ballistic Limit - Threat 2

MC02887

ATEK17-002-IIIA-MInitial Issue

200818-0 National Technical Systems-Wichita Division

THREAT DESCRIPTION

Sample 1 Sample 2 Sample 3

TEST DESCRIPTION

THREAT DESCRIPTION

Sample 21 Sample 22 Sample 23

Environmental Conditioned Armors

3A

Sample 13

MC02887

Sample 26 Sample 27Ballistic Limit

Sample InformationPage 4 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

NVLAP Lab Code: Test Laboratory Name:Report Identification Number:

Issue / Revision Number:

Test ID: Report Date:

Manufacturer: NIJ Armor Type: 3A

Ammunition: Test Velocity: 448.1 Conditioning:

Sample 1 Size: Sample 2 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note

1 452.8 0 29.73 439.8 0 24.13 445.0 0 26.83 450.8 0 28.33 2 444.9 0 26.69 440.4 0 27.79 452.1 0 29.20 449.0 0 25.01 3 446.0 0 27.03 442.4 0 25.97 439.4 0 26.59 442.7 0 28.56 4 441.8 0 447.0 0 444.0 0 445.5 0 5 446.0 0 450.7 0 445.5 0 449.9 0 6 442.2 0 453.1 0 447.3 0 446.3 0 7 8

Perforations: 0 BFS Statistics: Count: 12Maximum BFS: 29.7 mm

Pass - No BFS greater than 44 mm

Sample 3 Size: Sample 4 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note

1 447.3 0 27.22 445.9 0 26.44 445.5 0 26.94 452.4 0 28.80 2 444.2 0 28.59 451.3 0 28.01 446.8 0 28.63 447.3 0 28.23 3 443.0 0 29.60 447.3 0 28.47 441.9 0 27.52 439.9 0 27.74 4 451.2 0 446.5 0 451.6 0 451.0 0 5 445.2 0 451.2 0 442.0 0 448.0 0 6 448.2 0 449.6 0 445.2 0 443.0 0 7 8

Perforations: 0 BFS Statistics: Count: 12Maximum BFS: 29.6 mm

Pass - No BFS greater than 44 mm

Initial Issue

.357 SIG

ATEK Defense Systems, LLC.

MC02887

New

Panel AC-5

Panel BC-5

Panel B

± 9.1 m/s125/FMJ

Penetration and BFS Summary Data06/26/17

Threat 1 - New Armor

200818-0 National Technical Systems-Wichita DivisionATEK17-002-IIIA-M

Panel A

C-1Panel A

(Pass)

Panel B

Summary: (Pass)

Panel BC-1

Summary:

Panel A

P-BFS SummaryPage 5 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Test Velocity: 435.9 Conditioning:

Sample 5 Size: Sample 6 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note

1 440.2 0 33.89 429.2 0 34.05 437.8 0 37.56 442.6 0 35.82 2 438.0 0 36.50 431.4 0 35.57 436.0 0 41.23 428.1 0 36.61 3 432.4 0 34.88 437.6 0 35.19 428.3 0 33.33 433.9 0 36.21 4 427.3 0 428.6 0 438.3 0 427.3 0 5 428.3 0 437.6 0 438.6 0 441.8 0 6 436.0 0 428.1 0 439.4 0 427.4 0 7 8

Perforations: 0 BFS Statistics: Count: 12Maximum BFS: 41.2 mm

Pass - No BFS greater than 44 mm

Sample 7 Size: Sample 8 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note

1 429.4 0 36.60 429.8 0 34.99 437.0 0 36.75 435.0 0 36.61 2 429.0 0 39.05 429.1 0 36.79 436.4 0 36.88 428.4 0 34.34 3 437.8 0 36.47 429.8 0 34.06 436.2 0 37.66 428.6 0 35.12 4 432.2 0 428.5 0 440.5 0 433.6 0 5 437.3 0 438.6 0 435.1 0 437.1 0 6 429.2 0 428.2 0 438.5 0 438.8 0 7 8

Perforations: 0 BFS Statistics: Count: 12Maximum BFS: 39.0 mm

C-1

Panel A Panel BC-5

(Pass)

Panel A

Panel A Panel B Panel A

Summary: (Pass)

Panel B

Panel BC-5

C-1

± 9.1 m/s

Summary:

New.44 Mag 240/SJHPThreat 2 - New Armor

P-BFS SummaryPage 6 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

(Pass - No BFS greater than 44 mm)

Ammunition: Test Velocity: 429.8 Conditioning:

Sample 21 Size: Sample 22 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note

1 435.8 0 29.71 438.8 0 27.07 432.6 0 28.93 428.5 0 28.04 2 437.4 0 26.44 439.4 0 28.44 429.2 0 30.30 433.7 0 29.51 3 436.3 0 28.06 424.4 0 27.31 425.8 0 30.84 437.1 0 28.59 4 425.5 0 433.7 0 429.0 0 435.2 0 5 433.6 0 429.8 0 431.4 0 436.3 0 6 436.5 0 431.0 0 436.8 0 434.8 0 7 8

Perforations: 0 Perforations: 0Maximum BFS: 29.71 mm (no requirement) Maximum BFS: 30.84 mm (no requirement)

Ammunition: Test Velocity: 408.4 Conditioning:

Sample 23 Size: Sample 24 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note (m/sec) (Y=1/N=0) (mm) Note

1 401.4 0 34.31 401.5 0 33.91 412.2 0 36.41 411.5 0 36.59 2 400.8 0 33.50 403.2 0 35.54 407.9 0 37.01 413.2 0 38.41 3 401.6 0 32.41 415.3 0 35.51 405.3 0 37.61 410.9 0 38.64 4 411.4 0 407.0 0 419.2 0 411.1 0 5 405.1 0 399.8 0 404.8 0 400.4 0 6 417.0 0 410.3 0 401.4 0 418.7 0 7 8

Perforations: 0 Perforations: 0Maximum BFS: 35.54 mm (no requirement) Maximum BFS: 38.64 mm (no requirement)

Perforations: This requirement is for all P-BFS tested samples - New and Conditioned0

Backface Signature: This requirement is for New armors onlyMaximum BFS: 41.2 mm

Summary: (Pass)

C-5Panel A Panel B

± 9.1 m/s

Compliance Test Report revision NIJ 0101.06 CTR 2-25 (2015-05-22) / MS Excel version 14.0 / Operating System version Windows (32-bit) NT 6.01

Threat 2 - Conditioned Armor

C-1

C-1Panel B

This armor model meets the BFS performance requirements of NIJ Standard-0101.06 Section 7.8.8 Item a.

(Pass) (Pass)

This armor model meets the perforation performance requirements of NIJ Standard-0101.06 Section 7.8.8.

Summary:

Overall P-BFS Summary

Panel BPanel A

Conditioned240/SJHP

Panel A

± 9.1 m/s

Panel A Panel B

(Pass)

Threat 1 - Conditioned Armor.357 SIG 125/FMJ

C-5

.44 Mag

Conditioned

P-BFS SummaryPage 7 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Test Velocity: 448.1 Conditioning: New

Sample 11 Sample 11 Sample 12 Sample 12 Sample 13

Panel A Panel B Panel A Panel B Panel A

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks

1 440.5 0 445.2 0 444.0 0 *Tested 6/15/17 450.4 0 *Tested 6/16/17 450.2 0 *Tested 6/16/172 472.3 0 480.5 0 483.8 0 480.8 0 485.1 03 507.1 0 508.9 0 518.7 0 513.6 0 510.0 04 534.9 1 542.2 1 538.5 0 541.6 0 541.4 15 517.6 0 519.6 0 559.3 1 559.9 1 511.0 06 532.8 1 535.5 0 540.6 1 542.7 0 530.8 07 513.0 0 545.1 1 516.6 0 555.5 0 556.0 18 536.8 0 535.2 1 537.2 0 578.6 1 539.7 19 549.2 0 510.6 0 552.6 1 558.5 1 526.0 010 564.8 1 496.8 0 533.4 1 541.5 0 542.0 111 545.8 1 527.7 1 517.4 0 559.5 1 523.1 012 536.7 1 518.7 1 535.2 0 549.8 1 533.8 0131415

Sample 13 Sample 14 Sample 14 Sample 15 Sample 15Panel B Panel A Panel B Panel A Panel B

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks

1 446.0 0 *Tested 6/20/17 446.5 0 451.5 0 450.1 0 450.9 02 474.0 0 473.9 0 476.6 0 478.1 0 483.9 03 507.2 0 510.0 0 504.4 0 506.9 0 512.2 04 540.2 1 540.6 1 536.0 1 541.2 1 533.9 15 520.3 0 518.3 0 510.7 0 523.5 0 512.6 06 534.0 0 526.9 0 531.3 0 531.1 0 530.0 07 539.2 1 537.1 0 542.7 0 542.1 1 544.0 08 522.4 0 549.9 1 549.9 0 533.0 1 555.5 19 537.4 1 537.4 1 561.4 1 515.6 0 541.7 110 516.7 0 525.3 1 555.5 0 532.5 1 530.9 111 531.6 1 510.9 0 568.8 0 518.1 0 523.1 012 522.0 0 517.3 0 572.3 1 529.0 0 538.1 0131415

Total Usable Shots: 120 Perforations below 457 m/s: 0Perforations (Complete Penetrations): 42

Stops (Partial Penetrations): 78

Regression Model:Model Parameters: Location -50.064161

Shape 0.09306866

Estimated V50: 537.9 m/s

Estimated V05: 506.3 m/s1661 (1661) ft/s

velocity (448.1 m/sec): 0.02%

± 9.1 m/s .357 SIGThreat 1 - New Armor

AcceptableAcceptable

LogisticRegression Analysis

Summary:

125/FMJ

Key to Remarks:a - Too close to edgeb - Too close to prior impactc - Impact on seam

AcceptableAcceptable

Probability of perforation at NIJ referenceAcceptable 0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

300 350 400 450 500 550 600 650

Pro

ba

bili

ty

Velocity (m/s)

Test Data and Regression Model

Test Data V Ref.

VTest + 9.1 Est. Response

Est. V50 Est. V05

BL SummaryPage 8 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Test Velocity: 435.9 Conditioning: New

Sample 16 Sample 16 Sample 17 Sample 17 Sample 18Panel A Panel B Panel A Panel B Panel A

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks

1 432.3 0 437.9 0 429.3 0 431.9 0 435.9 0 *Panel Tested: 6/16/172 469.8 0 468.0 1 466.7 0 466.8 1 468.0 03 491.9 1 443.3 0 503.8 1 450.1 0 503.7 14 482.9 1 455.6 0 482.4 0 452.6 1 475.3 05 457.9 0 467.1 0 486.8 0 438.3 0 485.3 06 470.1 0 475.7 0 497.1 1 449.7 0 493.8 17 474.0 1 490.8 1 485.3 1 476.4 1 485.1 18 468.4 0 466.8 1 478.2 1 459.2 1 466.7 09 476.8 0 463.5 1 465.9 0 443.1 0 475.3 010 495.2 1 439.1 0 474.4 0 457.1 0 495.4 011 478.6 1 467.1 0 489.3 0 464.3 0 501.8 112 470.9 0 481.8 1 499.8 0 475.3 1 489.1 0131415

Sample 18 Sample 19 Sample 19 Sample 20 Sample 20Panel B Panel A Panel B Panel A Panel B

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks

1 438.7 0 *Panel Tested: 6/15/17 435.4 0 432.3 0 437.6 0 439.8 02 467.8 0 463.2 0 469.5 1 471.9 0 466.0 03 496.7 0 503.3 1 440.3 0 502.0 1 495.4 14 520.9 1 477.0 1 452.7 0 475.6 0 478.2 05 509.3 1 451.5 0 464.2 0 488.8 0 485.2 16 490.2 0 470.2 0 473.1 0 498.3 1 478.4 07 498.1 0 480.4 0 484.7 1 493.1 1 487.3 08 501.9 1 488.0 1 478.9 1 471.2 0 498.6 19 493.0 0 479.4 0 467.2 0 472.7 0 486.2 110 499.7 1 494.5 1 480.4 0 473.2 0 481.2 011 496.8 0 472.3 1 488.1 1 506.7 1 481.3 112 502.5 1 465.6 0 479.0 1 494.3 0 483.8 0131415

Total Usable Shots: 120 Perforations below 445 m/s: 0Perforations (Complete Penetrations): 47

Stops (Partial Penetrations): 73

Regression Model:Model Parameters: Location -34.95551

Shape 0.07221081

Estimated V50: 484.1 m/s

Estimated V05: 443.3 m/s1454 (1454) ft/s

Probability of perforation at NIJ referencevelocity (435.9 m/sec): 2.99%

Threat 2 - New Armor

Acceptable

Acceptable

AcceptableAcceptable

Summary:

± 9.1 m/s .44 Mag

Acceptable

240/SJHP

Regression AnalysisLogistic

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

300 350 400 450 500 550 600 650

Pro

ba

bili

ty

Velocity (m/s)

Test Data and Regression Model

Test Data V Ref.

VTest + 9.1 Est. Response

Est. V50 Est. V05

BL SummaryPage 9 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Ammunition:Test Velocity: 429.8 Cond: Conditioned Test Velocity: 408.4 Cond: Conditioned

Sample 25 Sample 25 Sample 26 Sample 26Panel A Panel B Panel A Panel B

Shot Avg. Vel. Perf Avg. Vel. Perf Shot Avg. Vel. Perf Avg. Vel. Perf

Number (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks Num (m/sec) (Y=1/N=0) Remarks (m/sec) (Y=1/N=0) Remarks

1 424.4 0 423.6 0 1 416.8 0 399.7 02 454.7 0 448.5 0 2 446.2 0 419.1 03 476.7 0 473.6 0 3 468.0 1 447.0 04 492.4 0 500.3 0 4 441.6 0 476.1 15 512.8 0 536.8 1 5 456.2 0 458.0 06 550.6 1 512.9 1 6 466.8 1 459.0 07 516.9 1 490.1 0 7 439.4 0 477.0 18 478.1 0 497.9 1 8 464.0 1 464.2 19 501.9 1 494.0 0 9 452.9 0 462.6 010 476.9 0 502.2 1 10 469.2 1 472.4 111 499.5 0 487.4 0 11 453.5 0 448.0 012 510.0 0 496.2 0 12 468.4 1 464.5 013 1314 1415 15

Total Usable Shots: 24 Total Usable Shots: 24

Perforations (CP): 7 Perforations (CP): 9Stops (PP): 17 Stops (PP): 15

Perforations below 438.9 m/s: 0 Perforations below 417.5 m/s: 0

Regression Model: Regression Model:Model Parameters: Location -68.867134 Model Parameters: Location -666.21132

Shape 0.13592879 Shape 1.43616474

Estimated V50: 506.64 m/s Estimated V50: 463.88 m/s

Perforations below Vref + 9.1 m/sec: 0 This requirement is for all Ballistic Limit tested samples - New and Conditioned

This requirement is for New armors onlyThreat 1: 0.02%Threat 2: 2.99%

Probability of perforation at the P-BFS reference velocity

Regression Analysis

Overall Ballistic Limit Summary

Logistic

± 9.1 m/s ± 9.1 m/s

Threat 1 - Conditioned Armor.357 SIG 125/FMJ

Threat 2 - Conditioned Armor

Compliance Test Report revision NIJ 0101.06 CTR 2-25 (2015-05-22) / MS Excel version 14.0 / Operating System version Windows (32-bit) NT 6.01

Summary:

Acceptable

Regression AnalysisLogistic

AcceptableAcceptable

This armor model meets the low perforation velocity performance requirements of NIJ Standard-0101.06 Section 7.9.5.

This armor model meets the estimated V05 performance requirements of NIJ Standard-0101.06 Section 7.9.5.

Acceptable

240/SJHP.44 Mag

Summary:

BL SummaryPage 10 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

NVLAP Lab Code: Test Laboratory Name:Report Identification Number:

Issue / Revision Number:

Test ID: Report Date:

Manufacturer: NIJ Armor Type: 3A

Ammunition: Test Velocity: 1470 Conditioning:

Sample 1 Size: Sample 2 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note

1 1486 0 29.73 1443 0 24.13 1460 0 26.83 1479 0 28.33 2 1460 0 26.69 1445 0 27.79 1483 0 29.20 1473 0 25.01 3 1463 0 27.03 1451 0 25.97 1442 0 26.59 1452 0 28.56 4 1449 0 1467 0 1457 0 1462 0 5 1463 0 1479 0 1462 0 1476 0 6 1451 0 1487 0 1468 0 1464 0 7 8

Perforations: 0 BFS Statistics: Count: 12 Average: 27.16 mmMaximum BFS: 29.7 mm St. Dev: 1.66196 mm

Pass - No BFS greater than 44 mm

Sample 3 Size: Sample 4 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note

1 1468 0 27.22 1463 0 26.44 1462 0 26.94 1484 0 28.80 2 1457 0 28.59 1481 0 28.01 1466 0 28.63 1468 0 28.23 3 1453 0 29.60 1468 0 28.47 1450 0 27.52 1443 0 27.74 4 1480 0 1465 0 1482 0 1480 0 5 1461 0 1480 0 1450 0 1470 0 6 1470 0 1475 0 1461 0 1453 0 7 8

Perforations: 0 BFS Statistics: Count: 12 Average: 28.02 mmMaximum BFS: 29.6 mm St. Dev: 0.88828 mm

Pass - No BFS greater than 44 mm

200818-0 National Technical Systems-Wichita DivisionATEK17-002-IIIA-MInitial Issue

.357 SIG 125/FMJ ± 30 ft/s New

Penetration and BFS Summary DataMC02887 06/26/17

ATEK Defense Systems, LLC.

Threat 1 - New Armor

C-5 C-5Panel A Panel B Panel A Panel B

Summary: (Pass)

C-1 C-1Panel A Panel B Panel A Panel B

Summary: (Pass)

P-BFS Summary (ft)Page 11 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Test Velocity: 1430 Conditioning:

Sample 5 Size: Sample 6 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note

1 1444 0 33.89 1408 0 34.05 1436 0 37.56 1452 0 35.82 2 1437 0 36.50 1415 0 35.57 1430 0 41.23 1405 0 36.61 3 1419 0 34.88 1436 0 35.19 1405 0 33.33 1424 0 36.21 4 1402 0 1406 0 1438 0 1402 0 5 1405 0 1436 0 1439 0 1449 0 6 1430 0 1405 0 1442 0 1402 0 7 8

Perforations: 0 BFS Statistics: Count: 12 Average: 35.9 mmMaximum BFS: 41.2 mm St. Dev: 2.08571 mm

Pass - No BFS greater than 44 mm

Sample 7 Size: Sample 8 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note

1 1409 0 36.60 1410 0 34.99 1434 0 36.75 1427 0 36.61 2 1407 0 39.05 1408 0 36.79 1432 0 36.88 1406 0 34.34 3 1436 0 36.47 1410 0 34.06 1431 0 37.66 1406 0 35.12 4 1418 0 1406 0 1445 0 1423 0 5 1435 0 1439 0 1427 0 1434 0 6 1408 0 1405 0 1439 0 1440 0 7 8

Perforations: 0 BFS Statistics: Count: 12 Average: 36.28 mmMaximum BFS: 39.0 mm St. Dev: 1.42597 mm

(Pass - No BFS greater than 44 mm)

Threat 2 - New Armor.44 Mag 240/SJHP ± 30 ft/s New

C-5 C-5Panel A Panel B Panel A Panel B

Summary: (Pass)

C-1 C-1Panel A Panel B Panel A Panel B

Summary: (Pass)

P-BFS Summary (ft)Page 12 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Test Velocity: 1410 Conditioning:

Sample 21 Size: Sample 22 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note

1 1430 0 29.71 1440 0 27.07 1419 0 28.93 1406 0 28.04 2 1435 0 26.44 1442 0 28.44 1408 0 30.30 1423 0 29.51 3 1431 0 28.06 1392 0 27.31 1397 0 30.84 1434 0 28.59 4 1396 0 1423 0 1407 0 1428 0 5 1423 0 1410 0 1415 0 1431 0 6 1432 0 1414 0 1433 0 1427 0 7 8

Perforations: 0 Perforations: 0Maximum BFS: 29.7 mm (no requirement) Maximum BFS: 30.84 mm (no requirement)

Ammunition: Test Velocity: 1340 Conditioning:

Sample 23 Size: Sample 24 Size:

Shot Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS Avg. Vel. Perf BFS

Number (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note (ft/sec) (Y=1/N=0) (mm) Note

1 1317 0 34.31 1317 0 33.91 1352 0 36.41 1350 0 36.59 2 1315 0 33.50 1323 0 35.54 1338 0 37.01 1356 0 38.41 3 1318 0 32.41 1363 0 35.51 1330 0 37.61 1348 0 38.64 4 1350 0 1335 0 1375 0 1349 0 5 1329 0 1312 0 1328 0 1314 0 6 1368 0 1346 0 1317 0 1374 0 7 8

Perforations: 0 Perforations: 0Maximum BFS: 35.54 mm (no requirement) Maximum BFS: 38.64 mm (no requirement)

Perforations: This requirement is for all P-BFS tested samples - New and Conditioned0

Backface Signature: This requirement is for New armors onlyMaximum BFS: 41.2 mm

Threat 1 - Conditioned Armor.357 SIG 125/FMJ ± 30 ft/s Conditioned

C-5 C-1Panel A Panel B Panel A Panel B

Summary: (Pass) (Pass)

Threat 2 - Conditioned Armor.44 Mag 240/SJHP ± 30 ft/s Conditioned

C-5 C-1Panel A Panel B Panel A Panel B

Compliance Test Report revision NIJ 0101.06 CTR 2-25 (2015-05-22) / MS Excel version 14.0 / Operating System version Windows (32-bit) NT 6.01

Summary: (Pass) (Pass)

Overall P-BFS Summary

This armor model meets the perforation performance requirements of NIJ Standard-0101.06 Section 7.8.8.

This armor model meets the BFS performance requirements of NIJ Standard-0101.06 Section 7.8.8 Item a.

P-BFS Summary (ft)Page 13 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Test Velocity: 1470 Conditioning: New

Sample 11 Sample 11 Sample 12 Sample 12 Sample 13

Panel A Panel B Panel A Panel B Panel A

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks

1 1445 0 1461 0 1457 0 *Tested 6/15/17 1478 0 *Tested 6/16/17 1477 0 *Tested 6/16/172 1550 0 1576 0 1587 0 1577 0 1592 03 1664 0 1670 0 1702 0 1685 0 1673 04 1755 1 1779 1 1767 0 1777 0 1776 15 1698 0 1705 0 1835 1 1837 1 1677 06 1748 1 1757 0 1774 1 1781 0 1741 07 1683 0 1788 1 1695 0 1823 0 1824 18 1761 0 1756 1 1762 0 1898 1 1771 19 1802 0 1675 0 1813 1 1832 1 1726 010 1853 1 1630 0 1750 1 1777 0 1778 111 1791 1 1731 1 1698 0 1836 1 1716 012 1761 1 1702 1 1756 0 1804 1 1751 0131415

Sample 13 Sample 14 Sample 14 Sample 15 Sample 15Panel B Panel A Panel B Panel A Panel B

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks

1 1463 0 *Tested 6/20/17 1465 0 1481 0 1477 0 1479 02 1555 0 1555 0 1564 0 1569 0 1588 03 1664 0 1673 0 1655 0 1663 0 1680 04 1772 1 1774 1 1759 1 1776 1 1752 15 1707 0 1700 0 1676 0 1718 0 1682 06 1752 0 1729 0 1743 0 1742 0 1739 07 1769 1 1762 0 1781 0 1779 1 1785 08 1714 0 1804 1 1804 0 1749 1 1823 19 1763 1 1763 1 1842 1 1692 0 1777 110 1695 0 1723 1 1823 0 1747 1 1742 111 1744 1 1676 0 1866 0 1700 0 1716 012 1713 0 1697 0 1878 1 1736 0 1765 0131415

Total Usable Shots: 120 Perforations below 1500 ft/s: 0Perforations (Complete Penetrations): 42

Stops (Partial Penetrations): 78

Regression Model:Model Parameters: Location -171.09751

Shape 0.1

Estimated V50: 1765 ft/s

Estimated V05: 506.3 m/s0 (1661) ft/s

velocity (1470 ft/sec): 0.02%

Logistic

Probability of perforation at NIJ referenceAcceptable

Summary: Acceptable Acceptable

Key to Remarks:a - Too close to edgeb - Too close to prior impactc - Impact on seam

AcceptableAcceptable

Regression Analysis

Threat 1 - New Armor.357 SIG 125/FMJ ± 30 ft/s

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

900 1100 1300 1500 1700 1900 2100

Pro

ba

bili

ty

Velocity (ft/s)

Test Data and Regression Model

Test Data V Ref.

VTest +30 Est. Response

Est. V50 Est. V05

BL Summary (ft)Page 14 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Test Velocity: 1430 Conditioning: New

Sample 16 Sample 16 Sample 17 Sample 17 Sample 18Panel A Panel B Panel A Panel B Panel A

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks

1 1418 0 1437 0 1408 0 1417 0 1430 0 *Panel Tested: 6/16/172 1541 0 1535 1 1531 0 1531 1 1535 03 1614 1 1454 0 1653 1 1477 0 1653 14 1584 1 1495 0 1583 0 1485 1 1559 05 1502 0 1532 0 1597 0 1438 0 1592 06 1542 0 1561 0 1631 1 1475 0 1620 17 1555 1 1610 1 1592 1 1563 1 1592 18 1537 0 1531 1 1569 1 1507 1 1531 09 1564 0 1521 1 1529 0 1454 0 1559 010 1625 1 1441 0 1556 0 1500 0 1625 011 1570 1 1532 0 1605 0 1523 0 1646 112 1545 0 1581 1 1640 0 1559 1 1605 0131415

Sample 18 Sample 19 Sample 19 Sample 20 Sample 20Panel B Panel A Panel B Panel A Panel B

Shot Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf Avg. Vel. Perf

Number (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks

1 1439 0 *Panel Tested: 6/15/17 1428 0 1418 0 1436 0 1443 02 1535 0 1520 0 1540 1 1548 0 1529 03 1630 0 1651 1 1445 0 1647 1 1625 14 1709 1 1565 1 1485 0 1560 0 1569 05 1671 1 1481 0 1523 0 1604 0 1592 16 1608 0 1543 0 1552 0 1635 1 1570 07 1634 0 1576 0 1590 1 1618 1 1599 08 1647 1 1601 1 1571 1 1546 0 1636 19 1617 0 1573 0 1533 0 1551 0 1595 110 1639 1 1622 1 1576 0 1552 0 1579 011 1630 0 1550 1 1601 1 1662 1 1579 112 1649 1 1528 0 1572 1 1622 0 1587 0131415

Total Usable Shots: 120 Perforations below 1460 ft/s: 0Perforations (Complete Penetrations): 47

Stops (Partial Penetrations): 73

Regression Model:Model Parameters: Location -155.78161

Shape 0.1

Estimated V50: 1588 ft/s

Estimated V05: 443.3 m/s0 (1454) ft/s

Probability of perforation at NIJ referencevelocity (1430 ft/sec): 2.99%

Summary: Acceptable AcceptableAcceptableAcceptable

Regression AnalysisLogistic

Acceptable

Threat 2 - New Armor.44 Mag 240/SJHP ± 30 ft/s

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

900 1100 1300 1500 1700 1900 2100

Pro

ba

bili

ty

Velocity (ft/s)

Test Data and Regression Model

Test Data V Ref.

VTest + 30 Est. Response

Est. V50 Est. V05

BL Summary (ft)Page 15 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Ammunition: Ammunition:Test Velocity: 1410 Cond: Conditioned Test Velocity: 1340 Cond: Conditioned

Sample 25 Sample 25 Sample 26 Sample 26Panel A Panel B Panel A Panel B

Shot Avg. Vel. Perf Avg. Vel. Perf Shot Avg. Vel. Perf Avg. Vel. Perf

Number (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks Number (ft/sec) (Y=1/N=0) Remarks (ft/sec) (Y=1/N=0) Remarks

1 1392 0 1390 0 1 1367 0 1311 02 1492 0 1471 0 2 1464 0 1375 03 1564 0 1554 0 3 1535 1 1467 04 1615 0 1641 0 4 1449 0 1562 15 1682 0 1761 1 5 1497 0 1503 06 1806 1 1683 1 6 1531 1 1506 07 1696 1 1608 0 7 1442 0 1565 18 1569 0 1634 1 8 1522 1 1523 19 1647 1 1621 0 9 1486 0 1518 010 1565 0 1648 1 10 1539 1 1550 111 1639 0 1599 0 11 1488 0 1470 012 1673 0 1628 0 12 1537 1 1524 013 1314 1415 15

Total Usable Shots: 24 Total Usable Shots: 24Perforations (CP): 7 Perforations (CP): 9

Stops (PP): 17 Stops (PP): 15

Perforations below 1440 ft/s: 0 Perforations below 1370 ft/s: 0

Regression Model: Regression Model:Model Parameters: Location -527.35224 Model Parameters: Location -15.2

Shape 0.1 Shape 0.008

Estimated V50: 1662 ft/s Estimated V50: 1522 ft/s

Perforations below Vref + 30 ft/sec: 0 This requirement is for all Ballistic Limit tested samples - New and Conditioned

This requirement is for New armors onlyThreat 1: 0.02%Threat 2: 2.99%

Regression Analysis Regression Analysis

Compliance Test Report revision NIJ 0101.06 CTR 2-25 (2015-05-22) / MS Excel version 14.0 / Operating System version Windows (32-bit) NT 6.01

Logistic Logistic

Overall Ballistic Limit Summary

This armor model meets the low perforation velocity performance requirements of NIJ Standard-0101.06 Section 7.9.5.

Probability of perforation at the P-BFS reference velocity

This armor model meets the estimated V05 performance requirements of NIJ Standard-0101.06 Section 7.9.5.

Acceptable Acceptable

Summary: Summary:Acceptable Acceptable

± 30 ft/s ± 30 ft/s

Threat 1 - Conditioned Armor Threat 2 - Conditioned Armor.357 SIG 125/FMJ .44 Mag 240/SJHP

BL Summary (ft)Page 16 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 12:37 HH:mm Indent: 18.61 17.64 18.93 18.00 17.36 18.11

Clay Temperature: 99.3 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 12:40 HH:mm

Ambient Temp: 73 73 F End: HH:mm End: 12:48 HH:mm

Rel. Humidity: 60 60 % Duration: min Duration: 8 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3369 1484 2747 1487 1486 0º Yes 0 29.73

2 3428 1459 2796 1461 1460 0º Yes 0 26.69

3 3421 1462 2789 1465 1463 0º Yes 0 27.03

4 3453 1448 2815 1451 1450 30º Yes 0

5 3421 1462 2789 1465 1463 45º Yes 0

6 3449 1450 2813 1452 1451 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Firing Sequence

024 N/A

Panel A

06/26/17

12:00

12:30

Comments

Panel A

Penetration and BFS Firing Data - New Armor - Threat 1

30

Armor Submersion

Sample 1

Drop Number

ATEK Defense Systems, LLC.

3A

MC02887

Drop Number

P-BFS New T1 S01Page 18 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

06/26/17

Penetration and BFS Firing Data - New Armor - Threat 1

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 12:53 HH:mm Indent: 20.01 18.61 19.22 19.30 17.76 18.98

Clay Temperature: 99.0 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 13:00 HH:mm

Ambient Temp: 73 73 F End: HH:mm End: 13:08 HH:mm

Rel. Humidity: 60 60 % Duration: min Duration: 8 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3467 1442 2829 1444 1443 0º Yes 0 24.13

2 3463 1444 2825 1446 1445 0º Yes 0 27.79

3 3448 1450 2812 1453 1451 0º Yes 0 25.97

4 3413 1465 2783 1468 1466 45º Yes 0

5 3385 1477 2760 1480 1479 30º Yes 0

6 3367 1485 2745 1488 1487 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

12:20

N/APanel B

Drop Number

Panel B

Sample 1

Comments

025

Drop Number

Armor Submersion Firing Sequence

12:50

30

P-BFS New T1 S01Page 19 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 13:14 HH:mm Indent: 20.55 19.05 19.36 20.16 17.45 19.31

Clay Temperature: 98.6 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 13:20 HH:mm

Ambient Temp: 73 73 F End: HH:mm End: 13:28 HH:mm

Rel. Humidity: 60 59 % Duration: min Duration: 8 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3428 1459 2795 1462 1460 0º Yes 0 26.83

2 3374 1482 2751 1485 1483 0º Yes 0 29.20

3 3472 1440 2831 1443 1442 0º Yes 0 26.59

4 3436 1455 2801 1458 1457 45º Yes 0

5 3424 1460 2792 1463 1462 30º Yes 0

6 3410 1466 2781 1469 1468 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

30

Comments

Panel A

Drop Number

Penetration and BFS Firing Data - New Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

3A

Sample 2

Drop Number

Armor Submersion Firing Sequence

12:40

MC02887

13:10

Panel A022 N/A

P-BFS New T1 S02Page 20 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Penetration and BFS Firing Data - New Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 13:35 HH:mm Indent: 19.69 18.70 19.19 18.48 17.11 18.63

Clay Temperature: 98.0 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 13:40 HH:mm

Ambient Temp: 73 73 F End: HH:mm End: 13:48 HH:mm

Rel. Humidity: 58 59 % Duration: min Duration: 8 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3385 1477 2759 1481 1479 0º Yes 0 28.33

2 3398 1471 2770 1475 1473 0º Yes 0 25.01

3 3446 1451 2810 1454 1452 0º Yes 0 28.56

4 3424 1460 2792 1463 1462 30º Yes 0

5 3391 1474 2765 1477 1476 45º Yes 0

6 3419 1462 2787 1466 1464 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 13:54 HH:mm Indent: 18.96 17.66 18.50 18.75 17.05 18.18

Clay Temperature: 97.6 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Comments

Panel B030 N/A

Drop Number

Armor Submersion Firing Sequence

13:00

13:30

30

Panel B

Sample 2

P-BFS New T1 S02Page 21 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 14:19 HH:mm Indent: 21.89 20.70 20.33 21.27 19.73 20.78

Clay Temperature: 97.8 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 14:25 HH:mm

Ambient Temp: 73 74 F End: HH:mm End: 14:32 HH:mm

Rel. Humidity: 59 60 % Duration: min Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3410 1466 2781 1469 1468 0º Yes 0 27.22

2 3434 1456 2800 1459 1457 0º Yes 0 28.59

3 3444 1452 2808 1455 1453 0º Yes 0 29.60

4 3381 1479 2757 1482 1480 30º Yes 0

5 3427 1459 2794 1462 1461 45º Yes 0

6 3404 1469 2775 1472 1470 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

30

Comments

Panel A

Drop Number

Penetration and BFS Firing Data - New Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

3A

Sample 3

Drop Number

Armor Submersion Firing Sequence

13:45

MC02887

14:15

Panel A003 N/A

P-BFS New T1 S03Page 22 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Penetration and BFS Firing Data - New Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 14:39 HH:mm Indent: 21.22 20.01 20.62 21.05 18.63 20.31

Clay Temperature: 97.2 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 14:45 HH:mm

Ambient Temp: 74 74 F End: HH:mm End: 14:52 HH:mm

Rel. Humidity: 61 60 % Duration: min Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3421 1462 2790 1464 1463 0º Yes 0 26.44

2 3380 1479 2756 1482 1481 0º Yes 0 28.01

3 3410 1466 2781 1469 1468 0º Yes 0 28.47

4 3417 1463 2786 1466 1465 45º Yes 0

5 3381 1479 2757 1482 1480 30º Yes 0

6 3393 1474 2767 1476 1475 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Comments

Panel B002 N/A

Drop Number

Armor Submersion Firing Sequence

14:05

14:35

30

Panel B

Sample 3

P-BFS New T1 S03Page 23 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 14:57 HH:mm Indent: 20.55 19.60 19.25 19.75 17.20 19.27

Clay Temperature: 96.8 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 15:05 HH:mm

Ambient Temp: 74 74 F End: HH:mm End: 15:12 HH:mm

Rel. Humidity: 60 60 % Duration: min Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3424 1460 2792 1463 1462 0º Yes 0 26.94

2 3414 1465 2784 1467 1466 0º Yes 0 28.63

3 3452 1448 2815 1451 1450 0º Yes 0 27.52

4 3378 1480 2754 1483 1482 45º Yes 0

5 3451 1449 2814 1452 1450 30º Yes 0

6 3427 1459 2794 1462 1461 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

30

Comments

Panel A

Drop Number

Penetration and BFS Firing Data - New Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

3A

Sample 4

Drop Number

Armor Submersion Firing Sequence

14:25

MC02887

14:55

Panel A001 N/A

P-BFS New T1 S04Page 24 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1470 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Penetration and BFS Firing Data - New Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 15:18 HH:mm Indent: 20.05 19.96 19.37 19.63 17.06 19.21

Clay Temperature: 96.3 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 15:25 HH:mm

Ambient Temp: 74 74 F End: HH:mm End: 15:32 HH:mm

Rel. Humidity: 60 61 % Duration: min Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3373 1482 2749 1486 1484 0º Yes 0 28.80

2 3410 1466 2781 1469 1468 0º Yes 0 28.23

3 3467 1442 2828 1444 1443 0º Yes 0 27.74

4 3383 1478 2758 1481 1480 30º Yes 0

5 3405 1468 2777 1471 1470 45º Yes 0

6 3444 1452 2808 1455 1453 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 15:38 HH:mm Indent: 18.25 17.56 18.60 18.28 17.01 17.94

Clay Temperature: 95.9 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Comments

Panel B011 N/A

Drop Number

Armor Submersion Firing Sequence

14:45

15:15

30

Panel B

Sample 4

P-BFS New T1 S04Page 25 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 7 Depth of 1 2 3 4 5 Avg.Time of Day: 9:34 HH:mm Indent: 19.84 19.99 18.88 20.13 19.29 19.63

Clay Temperature: 99.7 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 9:40 HH:mm

Ambient Temp: 70 71 F End: HH:mm End: 9:50 HH:mm

Rel. Humidity: 58 58 % Duration: min Duration: 10 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3465 1443 2826 1446 1444 0º Yes 0 33.89

2 3482 1436 2840 1438 1437 0º Yes 0 36.50

3 3528 1417 2877 1420 1419 0º Yes 0 34.88

4 3570 1401 2911 1403 1402 30º Yes 0

5 3561 1404 2905 1406 1405 45º Yes 0

6 3499 1429 2853 1432 1430 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

30

Comments

Panel A

Drop Number

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

Sample 5

Drop Number

Armor Submersion Firing Sequence

9:00

MC02887

9:30

Panel A031 N/A

P-BFS New T2 S05Page 26 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 7 Depth of 1 2 3 4 5 Avg.Time of Day: 9:57 HH:mm Indent: 20.20 20.29 21.21 21.04 18.72 20.29

Clay Temperature: 99.1 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 10:00 HH:mm

Ambient Temp: 71 71 F End: HH:mm End: 10:09 HH:mm

Rel. Humidity: 58 59 % Duration: min Duration: 9 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3554 1407 2899 1409 1408 0º Yes 0 34.05

2 3528 1417 2890 1413 1415 0º Yes 0 35.57

3 3486 1434 2843 1437 1436 0º Yes 0 35.19

4 3559 1405 2902 1408 1406 45º Yes 0

5 3486 1434 2843 1437 1436 30º Yes 0

6 3563 1403 2906 1406 1405 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Comments

Panel B032 N/A

Drop Number

Armor Submersion Firing Sequence

9:20

9:50

30

Panel B

Sample 5

P-BFS New T2 S05Page 27 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 7 Depth of 1 2 3 4 5 Avg.Time of Day: 10:14 HH:mm Indent: 21.51 19.24 20.79 21.07 18.03 20.13

Clay Temperature: 98.5 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 10:20 HH:mm

Ambient Temp: 71 71 F End: HH:mm End: 10:31 HH:mm

Rel. Humidity: 59 60 % Duration: min Duration: 11 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3484 1435 2841 1438 1437 0º Yes 0 37.56

2 3498 1429 2854 1431 1430 0º Yes 0 41.23

3 3562 1404 2904 1407 1405 0º Yes 0 33.33

4 3480 1437 2838 1439 1438 45º Yes 0

5 3478 1438 2836 1440 1439 30º Yes 0

6 3471 1441 2831 1443 1442 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

30

Comments

Panel A

Drop Number

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

Sample 6

Drop Number

Armor Submersion Firing Sequence

9:40

MC02887

10:10

Panel A021 N/A

P-BFS New T2 S06Page 28 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 7 Depth of 1 2 3 4 5 Avg.Time of Day: 10:37 HH:mm Indent: 21.20 20.20 20.93 20.79 18.21 20.27

Clay Temperature: 97.9 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 10:40 HH:mm

Ambient Temp: 71 71 F End: HH:mm End: 10:50 HH:mm

Rel. Humidity: 60 60 % Duration: min Duration: 10 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3446 1451 2811 1453 1452 0º Yes 0 35.82

2 3563 1403 2906 1406 1405 0º Yes 0 36.61

3 3516 1422 2867 1425 1423 0º Yes 0 36.21

4 3570 1401 2911 1403 1402 30º Yes 0

5 3452 1448 2816 1451 1450 45º Yes 0

6 3569 1401 2910 1404 1402 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: 7 Depth of 1 2 3 4 5 Avg.Time of Day: 10:54 HH:mm Indent: 19.98 18.55 18.62 19.01 17.10 18.65

Clay Temperature: 97.3 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Comments

Panel B023 N/A

Drop Number

Armor Submersion Firing Sequence

10:00

10:30

30

Panel B

Sample 6

P-BFS New T2 S06Page 29 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 7:56 HH:mm Indent: 20.05 17.70 19.56 18.89 17.69 18.78

Clay Temperature: 99.5 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 8:00 HH:mm

Ambient Temp: 70 70 F End: HH:mm End: 8:12 HH:mm

Rel. Humidity: 59 60 % Duration: min Duration: 12 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3553 1407 2897 1410 1409 0º Yes 0 36.60

2 3555 1406 2900 1409 1408 0º Yes 0 39.05

3 3484 1435 2841 1438 1437 0º Yes 0 36.47

4 3529 1417 2878 1419 1418 30º Yes 0

5 3488 1433 2845 1436 1435 45º Yes 0

6 3554 1407 2898 1410 1408 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

30

Comments

Panel A

Drop Number

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

Sample 7

Drop Number

Armor Submersion Firing Sequence

7:20

MC02887

7:50

Panel A006 N/A

P-BFS New T2 S07Page 30 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 8:18 HH:mm Indent: 21.79 20.32 20.27 20.51 17.89 20.16

Clay Temperature: 99.0 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 8:20 HH:mm

Ambient Temp: 70 70 F End: HH:mm End: 8:31 HH:mm

Rel. Humidity: 60 60 % Duration: min Duration: 11 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3549 1409 2894 1412 1410 0º Yes 0 34.99

2 3555 1406 2899 1409 1408 0º Yes 0 36.79

3 3549 1409 2895 1411 1410 0º Yes 0 34.06

4 3560 1404 2903 1407 1406 45º Yes 0

5 3478 1438 2836 1440 1439 30º Yes 0

6 3562 1404 2906 1406 1405 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Comments

Panel B007 N/A

Drop Number

Armor Submersion Firing Sequence

7:40

8:10

30

Panel B

Sample 7

P-BFS New T2 S07Page 31 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 8:37 HH:mm Indent: 21.25 19.04 21.23 19.13 17.56 19.64

Clay Temperature: 98.6 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 8:40 HH:mm

Ambient Temp: 70 70 F End: HH:mm End: 8:50 HH:mm

Rel. Humidity: 60 60 % Duration: min Duration: 10 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3490 1433 2847 1435 1434 0º Yes 0 36.75

2 3495 1431 2851 1433 1432 0º Yes 0 36.88

3 3497 1430 2852 1432 1431 0º Yes 0 37.66

4 3463 1444 2824 1447 1445 45º Yes 0

5 3506 1426 2859 1429 1427 30º Yes 0

6 3479 1437 2837 1440 1439 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

30

Comments

Panel A

Drop Number

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

Sample 8

Drop Number

Armor Submersion Firing Sequence

8:00

MC02887

8:30

Panel A008 N/A

P-BFS New T2 S08Page 32 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/12/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1430 ± 30 ft/s

NIJ Armor Type: Conditioning: NewTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Zerger

Penetration and BFS Firing Data - New Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

3A

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 8:56 HH:mm Indent: 20.99 18.97 18.02 19.08 17.12 18.84

Clay Temperature: 97.9 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: HH:mm Start: 9:00 HH:mm

Ambient Temp: 70 70 F End: HH:mm End: 9:10 HH:mm

Rel. Humidity: 60 59 % Duration: min Duration: 10 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3506 1426 2860 1428 1427 0º Yes 0 36.61

2 3560 1404 2904 1407 1406 0º Yes 0 34.34

3 3559 1405 2903 1407 1406 0º Yes 0 35.12

4 3518 1421 2869 1424 1423 30º Yes 0

5 3489 1433 2846 1435 1434 45º Yes 0

6 3477 1438 2835 1441 1439 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 9:16 HH:mm Indent: 20.80 18.99 18.76 19.11 17.19 18.97

Clay Temperature: 97.6 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Comments

Panel B012 N/A

Drop Number

Armor Submersion Firing Sequence

8:20

8:50

30

Panel B

Sample 8

P-BFS New T2 S08Page 33 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 18.8 18.77 20.55 18.96 19.95 19.41

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 74.8 F Start: HH:mm

Rel. Humidity: 53 % End: HH:mm

Duration: min

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.2 3463 1444 2824 1447 1445 X Y

2 8 3230 1548 2634 1551 1549 X Y

3 8.8 3008 1662 2453 1665 1664 X Y

4 9.6 2852 1753 2325 1757 1755 X Y

5 9 2947 1697 2403 1700 1698 X Y

6 9.5 2864 1746 2334 1750 1748 X Y

7 9 2974 1681 2424 1685 1683 X Y

8 9.5 2842 1759 2317 1763 1761 X Y

9 10 2778 1800 2265 1804 1802 X Y

10 10.5 2701 1851 2202 1855 1853 X Y

11 10 2795 1789 2279 1792 1791 X Y

12 9.5 2843 1759 2317 1763 1761 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Ballistic Limit Firing Data - New Armor - Threat 1

MC02887

N/A

214:21

14:40

Elston

100.9

BL PANEL 1 - A

Firing Sequence

14:29

11

Remarks

Result

033

Panel A

New1470 ± 30 ft/s

3A

06/15/17

ATEK Defense Systems, LLC.

06/26/17

.357 SIG 125/FMJ

Wilson

Sample 11

BL New T1 S11Page 34 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Ballistic Limit Firing Data - New Armor - Threat 1

MC02887

Elston

New1470 ± 30 ft/s

3A

06/15/17

ATEK Defense Systems, LLC.

06/26/17

.357 SIG 125/FMJ

Wilson

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.85 20.04 20.57 20.55 20.07 20.62

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 56 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3426 1459 2794 1462 1461 X Y

2 8.1 3175 1575 2589 1578 1576 X Y

3 8.9 2997 1668 2445 1671 1670 X Y

4 9.7 2812 1778 2295 1780 1779 X Y

5 9.1 2935 1704 2395 1706 1705 X Y

6 9.5 2849 1755 2323 1759 1757 X Y

7 10 2799 1786 2282 1790 1788 X Y

8 9.5 2851 1754 2324 1758 1756 X Y

9 9 2988 1673 2436 1677 1675 X Y

10 9.5 3071 1628 2504 1631 1630 X Y

11 9.2 2891 1730 2357 1733 1731 X Y

12 9 2941 1700 2398 1704 1702 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

14:49

Sample 11

2

99.7

Result

N/A

Panel B

034

Firing Sequence

15:18

20

Remarks

BL PANEL 2 - B

14:58

BL New T1 S11Page 35 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.53 21.08 20.61 20.52 19.80 20.51

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 55 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3436 1455 2802 1458 1457 X Y

2 8.1 3153 1586 2571 1589 1587 X Y

3 8.9 2941 1700 2398 1704 1702 X Y

4 9.7 2833 1765 2310 1768 1767 X Y

5 10.5 2728 1833 2224 1837 1835 X Y

6 9.9 2822 1772 2301 1775 1774 X Y

7 8.9 2953 1693 2408 1696 1695 X Y

8 9.6 2840 1761 2315 1765 1763 X Y

9 10.2 2761 1811 2251 1815 1813 X Y

10 9.6 2860 1748 2332 1752 1750 X Y

11 8.9 2948 1696 2404 1699 1698 X Y

12 9.6 2851 1754 2324 1758 1756 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Wilson

Elston

15:42

Panel A

*Tested 6/15/17

15:2698.9

Firing Sequence

15:29

± 30 ft/s

Result

Remarks

2

.357 SIG 125/FMJ

3A New1470

Sample 12

ATEK Defense Systems, LLC.

035 N/A

13

BL PANEL 3 - A

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 1

BL New T1 S12Page 36 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

MC02887

Wilson

Elston

± 30 ft/s.357 SIG 125/FMJ

3A New1470

ATEK Defense Systems, LLC.

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 1

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.56 20.18 18.67 21.37 19.44 20.04

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 70.3 F Start: HH:mm

Rel. Humidity: 46 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3387 1476 2762 1479 1478 X Y

2 8.1 3173 1576 2587 1579 1577 X Y

3 8.9 2970 1684 2422 1687 1685 X Y

4 9.7 2817 1775 2296 1779 1777 X Y

5 10.5 2725 1835 2221 1839 1837 X Y

6 9.9 2811 1779 2292 1782 1781 X Y

7 10.4 2746 1821 2239 1824 1823 X Y

8 11 2636 1897 2150 1900 1898 X Y

9 10.5 2732 1830 2227 1834 1832 X Y

10 9.9 2817 1775 2297 1778 1777 X Y

11 10.5 2727 1834 2223 1838 1836 X Y

12 9.9 2775 1802 2262 1806 1804 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

8:36

8:58

22

BL PANEL 4 - B

Result

2

Sample 12

Panel B

053 N/A

Remarks

*Tested 6/16/17

8:3098.6

BL New T1 S12Page 37 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.19 20.64 19.86 21.01 20.26 20.39

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 70.8 F Start: HH:mm

Rel. Humidity: 56 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3389 1475 2763 1478 1477 X Y

2 8.1 3145 1590 2564 1593 1592 X Y

3 8.9 2991 1672 2439 1675 1673 X Y

4 9.7 2818 1774 2297 1778 1776 X Y

5 9.1 2986 1674 2434 1678 1676 X Y

6 9.5 2874 1740 2343 1743 1742 X Y

7 9.9 2744 1822 2237 1826 1824 X Y

8 9.7 2827 1769 2304 1773 1771 X Y

9 9.3 2900 1724 2365 1727 1726 X Y

10 9.7 2815 1776 2295 1780 1778 X Y

11 9.3 2916 1715 2378 1718 1716 X Y

12 9.7 2858 1749 2330 1753 1751 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Wilson

Nguyen

9:44

Panel A

*Tested 6/16/17

9:1898.2

Firing Sequence

9:27

± 30 ft/s

Result

Remarks

2

.357 SIG 125/FMJ

3A New1470

Sample 13

ATEK Defense Systems, LLC.

037 N/A

17

BL PANEL 5 - A

06/26/17 06/16/17

Ballistic Limit Firing Data - New Armor - Threat 1

BL New T1 S13Page 38 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

MC02887

Wilson

Nguyen

± 30 ft/s.357 SIG 125/FMJ

3A New1470

ATEK Defense Systems, LLC.

06/26/17 06/16/17

Ballistic Limit Firing Data - New Armor - Threat 1

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 17.45 18.53 17.51 19.02 17.95 18.09

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 74.4 F Start: HH:mm

Rel. Humidity: 54 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3420 1462 2789 1465 1463 X Y

2 8.1 3218 1554 2624 1557 1555 X Y

3 8.9 3007 1663 2453 1665 1664 X Y

4 9.7 2824 1771 2303 1774 1772 X Y

5 9.1 2932 1705 2391 1708 1707 X Y

6 9.5 2857 1750 2329 1754 1752 X Y

7 9.9 2829 1767 2307 1771 1769 X Y

8 9.2 2920 1712 2381 1716 1714 X Y

9 9.6 2838 1762 2315 1765 1763 X Y

10 9.2 2953 1693 2407 1697 1695 X Y

11 9.5 2870 1742 2340 1746 1744 X Y

12 9.2 2922 1711 2383 1714 1713 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

14:38

14:51

13

BL PANEL 6 - B

Result

11

Sample 13

Panel B

038 N/A

Remarks

*Tested 6/20/17

14:2598.9

BL New T1 S13Page 39 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 18.38 18.61 20.14 20.75 17.56 19.09

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 74.6 F Start: HH:mm

Rel. Humidity: 54 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3416 1464 2786 1466 1465 X Y

2 8.1 3219 1553 2625 1556 1555 X Y

3 8.9 2991 1672 2439 1675 1673 X Y

4 9.7 2822 1772 2301 1775 1774 X Y

5 9.1 2943 1699 2400 1702 1701 X Y

6 9.5 2895 1727 2361 1730 1729 X Y

7 9.7 2840 1761 2316 1764 1762 X Y

8 10.1 2774 1802 2262 1806 1804 X Y

9 9.7 2838 1762 2315 1765 1763 X Y

10 9.3 2904 1722 2368 1725 1723 X Y

11 8.9 2985 1675 2435 1678 1676 X Y

12 9.3 2949 1695 2405 1699 1697 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Wilson

Elston

15:15

Panel A

14:5898.7

Firing Sequence

15:03

± 30 ft/s

Result

Remarks

11

.357 SIG 125/FMJ

3A New1470

Sample 14

ATEK Defense Systems, LLC.

039 N/A

12

BL PANEL 7 - A

06/26/17 06/20/17

Ballistic Limit Firing Data - New Armor - Threat 1

BL New T1 S14Page 40 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

MC02887

Wilson

Elston

± 30 ft/s.357 SIG 125/FMJ

3A New1470

ATEK Defense Systems, LLC.

06/26/17 06/20/17

Ballistic Limit Firing Data - New Armor - Threat 1

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.97 21.75 19.99 21.54 17.88 20.43

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 54 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3378 1480 2755 1483 1481 X Y

2 8.1 3201 1562 2610 1565 1564 X Y

3 8.9 3024 1653 2466 1657 1655 X Y

4 9.7 2846 1757 2321 1760 1758 X Y

5 9.1 2987 1674 2436 1677 1675 X Y

6 9.5 2871 1742 2341 1745 1743 X Y

7 9.9 2811 1779 2292 1782 1781 X Y

8 10.3 2774 1802 2262 1806 1804 X Y

9 10.7 2717 1840 2216 1843 1842 X Y

10 10.3 2746 1821 2239 1824 1823 X Y

11 10.7 2682 1864 2187 1868 1866 X Y

12 11.1 2665 1876 2174 1879 1878 X Y

13

14

15

Count: 12 3 9 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

15:24

15:35

11

BL PANEL 8 - B

Result

11

Sample 14

Panel B

040 N/A

Remarks

15:2098.1

BL New T1 S14Page 41 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 19.15 19.62 20.97 20.17 18.44 19.67

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 70.7 F Start: HH:mm

Rel. Humidity: 52 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3389 1475 2764 1478 1477 X Y

2 8.1 3191 1567 2602 1570 1568 X Y

3 8.9 3009 1662 2454 1665 1663 X Y

4 9.7 2819 1774 2298 1778 1776 X Y

5 9.1 2914 1716 2376 1719 1718 X Y

6 9.5 2872 1741 2342 1744 1743 X Y

7 9.9 2814 1777 2295 1780 1778 X Y

8 9.5 2862 1747 2334 1750 1749 X Y

9 9.1 2958 1690 2413 1693 1692 X Y

10 9.5 2865 1745 2336 1749 1747 X Y

11 9.1 2944 1698 2401 1701 1700 X Y

12 9.5 2883 1734 2352 1737 1736 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Wilson

Elston

8:05

Panel A

7:3499.6

Firing Sequence

7:47

± 30 ft/s

Result

Remarks

4

.357 SIG 125/FMJ

3A New1470

Sample 15

ATEK Defense Systems, LLC.

041 N/A

18

BL PANEL 9 - A

06/26/17 06/21/17

Ballistic Limit Firing Data - New Armor - Threat 1

BL New T1 S15Page 42 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

MC02887

Wilson

Elston

± 30 ft/s.357 SIG 125/FMJ

3A New1470

ATEK Defense Systems, LLC.

06/26/17 06/21/17

Ballistic Limit Firing Data - New Armor - Threat 1

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.23 21.65 20.50 19.03 18.69 20.22

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 71.2 F Start: HH:mm

Rel. Humidity: 52 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 7.3 3383 1478 2759 1481 1479 X Y

2 8.1 3153 1586 2570 1589 1588 X Y

3 8.9 2978 1679 2429 1682 1680 X Y

4 9.7 2857 1750 2330 1753 1752 X Y

5 9.1 2976 1680 2427 1683 1682 X Y

6 9.5 2878 1737 2347 1741 1739 X Y

7 9.9 2804 1783 2287 1786 1785 X Y

8 10.3 2746 1821 2239 1824 1823 X Y

9 9.9 2816 1776 2296 1779 1777 X Y

10 9.5 2873 1740 2343 1743 1742 X Y

11 9.1 2916 1715 2378 1718 1716 X Y

12 9.5 2835 1764 2312 1767 1765 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

8:17

8:31

14

BL PANEL 10 - B

Result

4

Sample 15

Panel B

042 N/A

Remarks

8:1299.5

BL New T1 S15Page 43 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.45 20.41 19.54 21.63 20.52 20.71

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 73 F Start: HH:mm

Rel. Humidity: 52 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3520 1420 2885 1416 1418 X Y

2 13.5 3238 1544 2655 1539 1541 X Y

3 15 3095 1616 2534 1612 1614 X Y

4 14 3151 1587 2582 1582 1584 X Y

5 13 3323 1505 2724 1500 1502 X Y

6 13.5 3236 1545 2653 1540 1542 X Y

7 14 3212 1557 2629 1554 1555 X Y

8 13.5 3249 1539 2662 1535 1537 X Y

9 14 3192 1566 2615 1562 1564 X Y

10 14.5 3074 1627 2517 1623 1625 X Y

11 14 3180 1572 2605 1568 1570 X Y

12 13.5 3233 1547 2647 1543 1545 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Zerger

Nold

9:00

Panel A

8:24100.3

Firing Sequence

8:35

± 30 ft/s

Result

Remarks

5

.44 Mag 240/SJHP

3A New1430

Sample 16

ATEK Defense Systems, LLC.

043 N/A

25

BL PANEL 11 - A

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

BL New T2 S16Page 44 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

MC02887

Zerger

Nold

± 30 ft/s.44 Mag 240/SJHP

3A New1430

ATEK Defense Systems, LLC.

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.13 20.45 19.56 20.13 19.47 20.15

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 74 F Start: HH:mm

Rel. Humidity: 52 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3474 1439 2848 1434 1437 X Y

2 13.5 3251 1538 2665 1533 1535 X Y

3 12.5 3431 1457 2814 1452 1454 X Y

4 13 3340 1497 2737 1493 1495 X Y

5 13.5 3258 1535 2670 1530 1532 X Y

6 14 3198 1563 2622 1558 1561 X Y

7 14.5 3101 1612 2540 1608 1610 X Y

8 14 3262 1533 2670 1530 1531 X Y

9 13.5 3284 1523 2690 1519 1521 X Y

10 13 3466 1443 2839 1439 1441 X Y

11 13.5 3257 1535 2670 1530 1533 X Y

12 14 3158 1583 2588 1578 1581 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

9:27

9:48

21

BL PANEL 12 - B

Result

5

Sample 16

Panel B

044 N/A

Remarks

9:19100.1

BL New T2 S16Page 45 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.83 21.52 18.27 19.03 20.47 20.02

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 74 F Start: HH:mm

Rel. Humidity: 52 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3552 1408 2898 1410 1409 X Y

2 13.5 3260 1534 2672 1529 1531 X Y

3 15 3023 1654 2473 1652 1653 X Y

4 14 3155 1585 2584 1581 1583 X Y

5 14.5 3126 1599 2562 1594 1597 X Y

6 15 3063 1632 2507 1629 1631 X Y

7 14.5 3138 1593 2568 1591 1592 X Y

8 14 3184 1570 2606 1568 1569 X Y

9 13.5 3265 1531 2677 1526 1529 X Y

10 14 3208 1559 2628 1554 1557 X Y

11 14.5 3110 1608 2548 1603 1605 X Y

12 15 3045 1642 2495 1637 1640 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Zerger

Nold

10:50

Panel A

10:1399.3

Firing Sequence

10:24

± 30 ft/s

Result

Remarks

5

.44 Mag 240/SJHP

3A New1430

Sample 17

ATEK Defense Systems, LLC.

045 N/A

26

BL PANEL 13 - A

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

BL New T2 S17Page 46 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

MC02887

Zerger

Nold

± 30 ft/s.44 Mag 240/SJHP

3A New1430

ATEK Defense Systems, LLC.

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.46 20.73 18.53 19.22 19.47 19.68

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 52 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3523 1419 2888 1414 1417 X Y

2 13.5 3259 1534 2672 1529 1532 X Y

3 12.5 3381 1479 2770 1475 1477 X Y

4 13 3362 1487 2755 1483 1485 X Y

5 12.5 3472 1440 2845 1436 1438 X Y

6 13 3383 1478 2773 1473 1476 X Y

7 13.5 3195 1565 2617 1561 1563 X Y

8 13 3314 1509 2716 1504 1506 X Y

9 12.5 3436 1455 2813 1452 1454 X Y

10 13 3328 1502 2729 1497 1500 X Y

11 13.5 3278 1525 2685 1521 1523 X Y

12 14 3202 1562 2623 1557 1559 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

11:05

11:23

18

BL PANEL 14 - B

Result

10

Sample 17

Panel B

046 N/A

Remarks

10:55100.4

BL New T2 S17Page 47 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.01 19.74 21.78 20.36 19.29 20.44

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 70.7 F Start: HH:mm

Rel. Humidity: 59 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3499 1429 2854 1431 1430 X Y

2 13.5 3254 1537 2663 1534 1535 X Y

3 15 3030 1650 2468 1655 1653 X Y

4 14 3204 1561 2622 1558 1559 X Y

5 14.5 3145 1590 2562 1594 1592 X Y

6 15 3091 1618 2518 1622 1620 X Y

7 14.2 3147 1589 2562 1594 1592 X Y

8 13.5 3263 1532 2670 1530 1531 X Y

9 14.1 3212 1557 2615 1562 1559 X Y

10 15.0 3081 1623 2510 1627 1625 X Y

11 15.5 3035 1647 2483 1645 1646 X Y

12 15.0 3121 1602 2542 1607 1605 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Zerger

Nold

7:52

Panel A

*Panel Tested: 6/16/17

7:2399.9

Firing Sequence

7:35

± 30 ft/s

Result

Remarks

2

.44 Mag 240/SJHP

3A New1430

Sample 18

ATEK Defense Systems, LLC.

036 N/A

17

BL PANEL 15 - A

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

BL New T2 S18Page 48 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

MC02887

Zerger

Nold

± 30 ft/s.44 Mag 240/SJHP

3A New1430

ATEK Defense Systems, LLC.

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.49 18.56 19.47 19.22 20.37 19.82

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 74 F Start: HH:mm

Rel. Humidity: 56 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3470 1441 2841 1438 1439 X Y

2 13.5 3254 1537 2665 1533 1535 X Y

3 15 3065 1631 2509 1628 1630 X Y

4 16.5 2924 1710 2392 1708 1709 X Y

5 15.5 2988 1673 2448 1669 1671 X Y

6 14.5 3105 1610 2543 1606 1608 X Y

7 15 3057 1636 2502 1633 1634 X Y

8 15.5 3034 1648 2483 1645 1647 X Y

9 15 3088 1619 2528 1616 1618 X Y

10 15.5 3046 1641 2495 1637 1639 X Y

11 15 3064 1632 2509 1628 1630 X Y

12 15.5 3030 1650 2480 1647 1649 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

13:51

14:07

16

BL PANEL 16 - B

Result

10

Sample 18

Panel B

048 N/A

Remarks

*Panel Tested: 6/15/17

13:4797.3

BL New T2 S18Page 49 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.73 20.46 20.18 20.33 20.16 20.57

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 57 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3494 1431 2865 1426 1428 X Y

2 13.5 3285 1522 2692 1517 1520 X Y

3 15 3026 1652 2476 1650 1651 X Y

4 14 3191 1567 2613 1563 1565 X Y

5 13 3370 1484 2762 1479 1481 X Y

6 13.5 3237 1545 2652 1540 1542 X Y

7 14.0 3169 1578 2595 1574 1576 X Y

8 14.5 3119 1603 2555 1599 1601 X Y

9 14.0 3175 1575 2601 1571 1573 X Y

10 14.5 3078 1624 2521 1620 1622 X Y

11 14.0 3222 1552 2640 1547 1550 X Y

12 13.5 3268 1530 2678 1525 1528 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Zerger

Nold

14:42

Panel A

14:1899.3

Firing Sequence

14:22

± 30 ft/s

Result

Remarks

12

.44 Mag 240/SJHP

3A New1430

Sample 19

ATEK Defense Systems, LLC.

049 N/A

20

BL PANEL 17 - A

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

BL New T2 S19Page 50 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

MC02887

Zerger

Nold

± 30 ft/s.44 Mag 240/SJHP

3A New1430

ATEK Defense Systems, LLC.

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.75 19.56 20.3 21.03 20.14 20.36

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 56 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3520 1420 2884 1416 1418 X Y

2 13.5 3241 1543 2656 1538 1540 X Y

3 12.5 3456 1447 2832 1442 1445 X Y

4 13 3363 1487 2753 1484 1485 X Y

5 13.5 3279 1525 2686 1521 1523 X Y

6 14 3216 1555 2636 1550 1552 X Y

7 14.5 3140 1592 2572 1588 1590 X Y

8 14.0 3178 1573 2603 1569 1571 X Y

9 13.5 3259 1534 2668 1531 1533 X Y

10 14 3168 1578 2595 1574 1576 X Y

11 14.5 3119 1603 2554 1599 1601 X Y

12 14 3177 1574 2603 1569 1572 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

15:00

15:19

19

BL PANEL 18 - B

Result

12

Sample 19

Panel B

050 N/A

Remarks

14:5399.6

BL New T2 S19Page 51 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.32 18.56 19.42 20.13 19.45 19.58

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 55 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3476 1438 2851 1433 1436 X Y

2 13.5 3225 1550 2642 1546 1548 X Y

3 15 3032 1649 2483 1645 1647 X Y

4 14 3201 1562 2621 1559 1560 X Y

5 14.5 3115 1605 2550 1602 1604 X Y

6 15 3054 1637 2502 1633 1635 X Y

7 14.5 3087 1620 2528 1616 1618 X Y

8 13.5 3231 1548 2645 1544 1546 X Y

9 14 3219 1553 2638 1549 1551 X Y

10 14.5 3215 1555 2636 1550 1552 X Y

11 15.5 3004 1664 2460 1661 1663 X Y

12 15.0 3079 1624 2522 1620 1622 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Zerger

Nold

15:44

Panel A

15:2798.7

Firing Sequence

15:31

± 30 ft/s

Result

Remarks

12

.44 Mag 240/SJHP

3A New1430

Sample 20

ATEK Defense Systems, LLC.

051 N/A

13

BL PANEL 19 - A

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

BL New T2 S20Page 52 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 3 Velocity 2: 4.085 ft. 1.245 m

MC02887

Zerger

Nold

± 30 ft/s.44 Mag 240/SJHP

3A New1430

ATEK Defense Systems, LLC.

06/26/17 06/15/17

Ballistic Limit Firing Data - New Armor - Threat 2

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.20 18.54 19.36 19.73 20.10 19.59

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 75 F Start: HH:mm

Rel. Humidity: 56 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 12 3461 1445 2834 1441 1443 X Y

2 13.5 3266 1531 2675 1527 1529 X Y

3 15 3072 1628 2517 1623 1625 X Y

4 14 3183 1571 2607 1567 1569 X Y

5 14.5 3138 1593 2569 1590 1592 X Y

6 14 3181 1572 2606 1568 1570 X Y

7 14.5 3123 1601 2559 1596 1599 X Y

8 15.0 3053 1638 2500 1634 1636 X Y

9 14.5 3131 1597 2564 1593 1595 X Y

10 14 3162 1581 2592 1576 1579 X Y

11 14.5 3161 1582 2591 1577 1579 X Y

12 14 3146 1589 2577 1585 1587 X Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

15:56

16:13

17

BL PANEL 20 - B

Result

12

Sample 20

Panel B

052 N/A

Remarks

15:5097.8

BL New T2 S20Page 53 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1410 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.5240 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.2451 m Wilson/Nold

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 7:34 HH:mm Indent: 20.99 21.12 19.34 21.10 18.47 20.2

Clay Temperature: 99.5 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 7:38 HH:mm

Ambient Temp: 70 71 F End: 7:44 HH:mm

Rel. Humidity: 57 61 % Duration: 6 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3500 1429 2854 1431 1430 0º Yes 0 29.71

2 3487 1434 2844 1436 1435 0º Yes 0 26.44

3 3496 1430 2851 1433 1432 0º Yes 0 28.06

4 3585 1395 2923 1398 1396 30º Yes 0

5 3518 1421 2869 1424 1423 45º Yes 0

6 3495 1431 2850 1433 1432 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Panel A

Comments

Drop Number

3A

Sample 21Panel A

020

Drop Number

Firing Sequence

Penetration and BFS Firing Data - Conditioned Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

N/A

MC02887

P-BFS Cond T1 S21Page 54 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1410 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.5240 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.2451 m Wilson/Nold

3A

Penetration and BFS Firing Data - Conditioned Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 7:50 HH:mm Indent: 21.83 19.11 19.34 21.06 21.74 20.62

Clay Temperature: 98.9 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 7:55 HH:mm

Ambient Temp: 71 71 F End: 8:02 HH:mm

Rel. Humidity: 61 58 % Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3476 1438 2835 1441 1440 0º Yes 0 27.07

2 3472 1440 2831 1443 1442 0º Yes 0 28.44

3 3594 1391 2931 1394 1392 0º Yes 0 27.31

4 3517 1422 2868 1424 1423 45º Yes 0

5 3550 1408 2894 1412 1410 30º Yes 0

6 3540 1412 2886 1415 1414 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Firing Sequence

Panel B

Comments

Panel B019 N/A

Drop Number

Sample 21

P-BFS Cond T1 S21Page 55 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1410 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Wilson/Nold

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 8:07 HH:mm Indent: 21.59 19.59 21.00 20.72 19.00 20.38

Clay Temperature: 97.9 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 8:10 HH:mm

Ambient Temp: 71 71 F End: 8:17 HH:mm

Rel. Humidity: 58 58 % Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3526 1418 2875 1421 1419 0º Yes 0 28.93

2 3554 1407 2898 1410 1408 0º Yes 0 30.30

3 3583 1395 2921 1398 1397 0º Yes 0 30.84

4 3556 1406 2900 1409 1407 45º Yes 0

5 3536 1414 2884 1416 1415 30º Yes 0

6 3492 1432 2848 1434 1433 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Panel A

Comments

Drop Number

3A

Sample 22Panel A

004

Drop Number

Firing Sequence

Penetration and BFS Firing Data - Conditioned Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

N/A

MC02887

P-BFS Cond T1 S22Page 56 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .357 SIG 125/FMJTest Velocity: 1410 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Wilson/Nold

3A

Penetration and BFS Firing Data - Conditioned Armor - Threat 1

06/26/17

ATEK Defense Systems, LLC.

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 8:25 HH:mm Indent: 21.10 20.95 18.84 21.00 18.06 19.99

Clay Temperature: 97.2 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 8:28 HH:mm

Ambient Temp: 71 71 F End: 8:35 HH:mm

Rel. Humidity: 58 58 % Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3560 1404 2903 1407 1406 0º Yes 0 28.04

2 3518 1421 2868 1424 1423 0º Yes 0 29.51

3 3490 1433 2846 1435 1434 0º Yes 0 28.59

4 3505 1427 2859 1429 1428 30º Yes 0

5 3496 1430 2851 1433 1432 45º Yes 0

6 3509 1425 2861 1428 1426 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: 8 Depth of 1 2 3 4 5 Avg.Time of Day: 8:40 HH:mm Indent: 20.85 19.97 19.59 20.10 18.01 19.7

Clay Temperature: 96.8 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Firing Sequence

Panel B

Comments

Panel B005 N/A

Drop Number

Sample 22

P-BFS Cond T1 S22Page 57 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1340 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Wilson/Nold

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 9:07 HH:mm Indent: 19.55 18.24 19.27 20.53 18.58 19.23

Clay Temperature: 99.4 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 9:12 HH:mm

Ambient Temp: 71 71 F End: 9:19 HH:mm

Rel. Humidity: 57 56 % Duration: 7 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3801 1315 3099 1318 1317 0º Yes 0 34.31

2 3806 1314 3104 1316 1315 0º Yes 0 33.50

3 3799 1316 3097 1319 1318 0º Yes 0 32.41

4 3708 1348 3023 1351 1350 30º Yes 0

5 3766 1328 3071 1330 1329 45º Yes 0

6 3658 1367 2983 1369 1368 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Panel A

Comments

Drop Number

3A

Sample 23Panel A

026

Drop Number

Firing Sequence

Penetration and BFS Firing Data - Conditioned Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

N/A

MC02887

P-BFS Cond T2 S23Page 58 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1340 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Wilson/Nold

3A

Penetration and BFS Firing Data - Conditioned Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 9:26 HH:mm Indent: 20.84 20.44 21.18 20.86 19.33 20.53

Clay Temperature: 99.0 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 9:30 HH:mm

Ambient Temp: 71 71 F End: 9:36 HH:mm

Rel. Humidity: 56 57 % Duration: 6 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3800 1316 3098 1319 1317 0º Yes 0 33.91

2 3783 1322 3085 1324 1323 0º Yes 0 35.54

3 3673 1361 2995 1364 1363 0º Yes 0 35.51

4 3748 1334 3056 1337 1335 45º Yes 0

5 3815 1311 3112 1313 1312 30º Yes 0

6 3718 1345 3032 1347 1346 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Firing Sequence

Panel B

Comments

Panel B015 N/A

Drop Number

Sample 23

P-BFS Cond T2 S23Page 59 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1340 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Wilson/Nold

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 9:42 HH:mm Indent: 21.83 20.57 20.88 20.22 18.74 20.45

Clay Temperature: 98.5 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 9:46 HH:mm

Ambient Temp: 71 71 F End: 9:56 HH:mm

Rel. Humidity: 57 56 % Duration: 10 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3700 1351 3018 1354 1352 0º Yes 0 36.41

2 3740 1337 3050 1339 1338 0º Yes 0 37.01

3 3764 1328 3069 1331 1330 0º Yes 0 37.61

4 3639 1374 2967 1377 1375 45º Yes 0

5 3769 1327 3073 1329 1328 30º Yes 0

6 3800 1316 3099 1318 1317 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: Depth of 1 2 3 4 5 Avg.Time of Day: HH:mm Indent:

Clay Temperature: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: -

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Panel A

Comments

Drop Number

3A

Sample 24Panel A

009

Drop Number

Firing Sequence

Penetration and BFS Firing Data - Conditioned Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

N/A

MC02887

P-BFS Cond T2 S24Page 60 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date: 06/22/17

Test ID:

Manufacturer: Ammunition: .44 Mag 240/SJHPTest Velocity: 1340 ± 30 ft/s

NIJ Armor Type: Conditioning: ConditionedTEST DIMENSIONS:

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m Lab Technician(s): Nguyen

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m Wilson/Nold

3A

Penetration and BFS Firing Data - Conditioned Armor - Threat 2

06/26/17

ATEK Defense Systems, LLC.

MC02887

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 10:01 HH:mm Indent: 20.33 20.03 21.44 21.14 18.90 20.37

Clay Temperature: 97.9 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Start End Start: 10:05 HH:mm

Ambient Temp: 71 72 F End: 10:13 HH:mm

Rel. Humidity: 57 56 % Duration: 8 min

Shot Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Fair Perforate BFS

No. (µs) (ft/s) (µs) (ft/s) (ft/s) Angle (Y/N) (Y=1/N=0) Note (mm)

1 3707 1349 3023 1351 1350 0º Yes 0 36.59

2 3692 1354 3011 1357 1355 0º Yes 0 38.41

3 3712 1347 3028 1349 1348 0º Yes 0 38.64

4 3710 1348 3026 1350 1349 30º Yes 0

5 3810 1312 3106 1315 1314 45º Yes 0

6 3643 1372 2971 1375 1374 0º Yes 0

7

8

POST-TEST CLAY VALIDATION:

Block ID: 9 Depth of 1 2 3 4 5 Avg.Time of Day: 10:18 HH:mm Indent: 20.98 18.52 19.20 19.31 17.88 19.18

Clay Temperature: 97.2 F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

NOTES:

a - Excessive velocity d - Too close to prior impact g - Impact on seam

b - Insufficient velocity e - Excessive total impacts (test terminated)

c - Too close to edge f - Excessive area impacts (test terminated)

Drop Number

Firing Sequence

Panel B

Comments

Panel B010 N/A

Drop Number

Sample 24

P-BFS Cond T2 S24Page 61 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 16.70 17.61 18.40 19.41 17.53 17.93

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 71.6 F Start: HH:mm

Rel. Humidity: 57 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 6.3 3595 1391 2931 1394 1392 X Y

2 6.9 3355 1490 2736 1493 1492 X Y

3 7.5 3200 1562 2609 1566 1564 X Y

4 8.2 3098 1614 2526 1617 1615 X Y

5 9 2975 1681 2426 1684 1682 X Y

6 10.2 2771 1804 2259 1808 1806 X Y

7 9.4 2951 1694 2407 1697 1696 X Y

8 8.2 3191 1567 2602 1570 1569 X Y

9 8.6 3040 1645 2478 1649 1647 X Y

10 8.3 3199 1563 2608 1566 1565 X Y

11 8.5 3054 1637 2490 1641 1639 X Y

12 8.7 2991 1672 2439 1675 1673 X Y

13

14

15

Count: 12 3 9 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Wilson

Nold

13:46

Panel A

13:26100.4

Firing Sequence

13:32

± 30 ft/s

Result

Remarks

2

.357 SIG 125/FMJ

3A Conditioned1410

Sample 25

ATEK Defense Systems, LLC.

027 N/A

14

BL PANEL 21 - A

06/26/17 06/22/17

Ballistic Limit Firing Data - Conditioned Armor - Threat 1

BL Cond T1 S25Page 62 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

MC02887

Wilson

Nold

± 30 ft/s.357 SIG 125/FMJ

3A Conditioned1410

ATEK Defense Systems, LLC.

06/26/17 06/22/17

Ballistic Limit Firing Data - Conditioned Armor - Threat 1

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 18.88 20.37 21.15 20.05 19.70 20.03

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 71.7 F Start: HH:mm

Rel. Humidity: 54 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 6.3 3601 1389 2937 1391 1390 X Y

2 6.9 3401 1470 2774 1473 1471 X Y

3 8.3 3221 1552 2627 1555 1554 X Y

4 8.6 3049 1640 2486 1643 1641 X Y

5 9.8 2841 1760 2318 1762 1761 X Y

6 8.8 2974 1681 2425 1685 1683 X Y

7 8.2 3113 1606 2538 1610 1608 X Y

8 8.6 3064 1632 2498 1635 1634 X Y

9 8.1 3088 1619 2518 1622 1621 X Y

10 8.7 3038 1646 2477 1649 1648 X Y

11 8 3130 1597 2552 1601 1599 X Y

12 8.7 3074 1627 2507 1629 1628 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

14:00

14:17

17

BL PANEL 22 - B

Result

2

Sample 25

Panel B

028 N/A

Remarks

13:5499.8

BL Cond T1 S25Page 63 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 20.98 20.56 20.72 21.12 18.50 20.38

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 72 F Start: HH:mm

Rel. Humidity: 55 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 14.7 3660 1366 2985 1369 1367 X Y

2 15.9 3418 1463 2788 1465 1464 X Y

3 17.2 3265 1531 2654 1539 1535 X Y

4 16.0 3447 1451 2823 1447 1449 X Y

5 16.6 3337 1498 2732 1495 1497 X Y

6 17.2 3268 1530 2665 1533 1531 X Y

7 16.6 3471 1441 2831 1443 1442 X Y

8 17.2 3293 1518 2676 1527 1522 X Y

9 16.6 3368 1485 2747 1487 1486 X Y

10 17.3 3251 1538 2651 1541 1539 X Y

11 16.6 3363 1487 2743 1489 1488 X Y

12 17.3 3256 1536 2656 1538 1537 x Y

13

14

15

Count: 12 5 7 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

MC02887

Nguyen

Wilson/Nold

11:16

Panel A

10:55100.2

Firing Sequence

11:01

± 30 ft/s

Result

Remarks

11

.44 Mag 240/SJHP

3A Conditioned1340

Sample 26

ATEK Defense Systems, LLC.

013 N/A

15

BL PANEL 23 - A

06/26/17 06/22/17

Ballistic Limit Firing Data - Conditioned Armor - Threat 2

BL Cond T2 S26Page 64 of 69NIJ CTR 2-25

For Test Laboratory Use NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT

NIJ 0101.06July 2008

Report Number: ATEK17-002-IIIA-M Report Date: Test Date:Test ID:

Manufacturer: Ammunition:Test Velocity:

NIJ Armor Type: Conditioning:TEST DIMENSIONS: Lab Technician(s):

Range Length: 16.40 ft. Velocity 1: 5.000 ft. 1.524 m

Laboratory Range #: 2 Velocity 2: 4.085 ft. 1.245 m

MC02887

Nguyen

Wilson/Nold

± 30 ft/s.44 Mag 240/SJHP

3A Conditioned1340

ATEK Defense Systems, LLC.

06/26/17 06/22/17

Ballistic Limit Firing Data - Conditioned Armor - Threat 2

Panel Serial No: Plate Serial No:

PRE-TEST CLAY VALIDATION:

Block ID: Drop 1 Drop 2 Drop 3 Drop 4 Drop 5 Avg.Time of Day: HH:mm Depth of Indent: 21.02 19.96 20.06 20.89 18.11 20.01

Clay Temp: F Requirements: All drops: 19 ± 3 mm , Average: 19 ± 2 mmPass: Yes

TEST CONDITIONS:

Ambient Temp: 72 F Start: HH:mm

Rel. Humidity: 55 % End: HH:mm

Duration: min

Enter NIJ Armor Types III and IV Sample Number(s) in Remarks Column as Applicable

Shot Charge Time 1 Vel. 1 Time 2 Vel. 2 Vel. Avg. Used

No. Weight (µs) (ft/s) (µs) (ft/s) (ft/s) Perf (CP) Stop (PP) (Y/N)

1 14.7 3816 1310 3112 1313 1311 X Y

2 15.7 3640 1374 2968 1376 1375 X Y

3 16.7 3413 1465 2783 1468 1467 X Y

4 17.5 3204 1561 2613 1563 1562 X Y

5 16.8 3331 1501 2716 1504 1503 X Y

6 17.4 3324 1504 2710 1507 1506 X Y

7 18 3198 1563 2608 1566 1565 X Y

8 17.4 3286 1522 2680 1524 1523 X Y

9 16.8 3297 1517 2689 1519 1518 X Y

10 17.5 3229 1548 2633 1551 1550 X Y

11 16.8 3404 1469 2777 1471 1470 X Y

12 17.4 3284 1523 2678 1525 1524 X Y

13

14

15

Count: 12 4 8 12

Remarks:

a - Too close to edge b - Too close to prior impact c - Impact on seam

Firing Sequence

11:29

11:45

16

BL PANEL 24 - B

Result

11

Sample 26

Back Panel

014 N/A

Remarks

11:2498.9

BL Cond T2 S26Page 65 of 69NIJ CTR 2-25