شرکت الکترو حرارت تدبیر پیشگام در سیستمهای گرمایش...
DESCRIPTION
شرکت الکترو حرارت تدبیر پیشگام در سیستمهای گرمایش الکتریکی. معرفی سیستم گرمایش الکتریکی مبتنی بر کابل Electrical Heat Tracing System. Website : www.ehs.ir Email : [email protected]. پیمایش گرمایی در صنعت (Trace Heating). جلوگیری از یخ زدگی Freeze Protection حفط دما Temperature Maintenance - PowerPoint PPT PresentationTRANSCRIPT
Electrical Heat Tracing SystemWebsite : www.ehs.irEmail : [email protected]
(Trace Heating) Freeze Protection
Temperature Maintenance
Heat Up
(Trace Heating) (Steam Tracing)
:
- (Electric Trace Heating)
...
- (Skin Effect)Tracer STS Systems can be designed for:Circuit lengths up to 25 kilometers (15 miles)Power outputs up to 150 W/m (49.2 W/ft)Maintain temperatures up to 200oC (392oF)Exposure temperatures up to 250oC (482oF)
(Constant Wattage Heating Cable) / (Pre-Manufactured) (Cut to Length)
(Self Regulating Heating Cable) Low Temperature Heating Cable Medium Temperature Heating Cable High Temperature Heating Cable Pre-Manufactured Single Conductor/Double-Side Power Supply PVC (80C) ELEKTRA VC/MD PTFE (250C) ELK-PTFE Eltrace Mineral Insulated(MI) Eltrace ELK-MISS Alloy 825 (600C)Inconel (800C)
7 Pre-Manufactured Double Conductor/Single-Side Power Supply PVC (80C) ELEKTRA VCD/VCDR PTFE (260C) Eltrace ELK-PTF
Mineral Insulated (MI) Eltrace ELK-MI
Cut to Length Eltrace ELP-SB
Self Regulating Heating Cable Single Side Power Supply
Self Regulating Heating Cable
Eltrace TRACECO- . . . . Cladding . .
Fine Korea Open Annealing ATEX (Hazardous Area) Fine ...
Fine ... Open Annealing . (Semi Permanent) 1012 102~103 PTC : Circuit Breaker . . . Bus Wire : Bus Wire Open Annealing 15 In Line Aging . Modified Polyethylene Fluoropolymer 100C HDPE PVDF LDPE ETFE PVDF = Polyvinylidene fluoride ETFE = Ethylene tetrafluoroethylene Polyester Elastomer (200C ) Cross-Linking .
Fine KoreaShell Mossmorran Design and replace Trace Heating on NGL tanks, 300,000, SRM 50-2CT
Sakhalin (Shell) Design supply and install Instrument Trace Heating and insulation,400,000, SRF30-2CR
AGIP KCO Kashagan Supply Instrument Trace Heating and insulation,350,000,SRF30-2CR,SRM30-2CR
Iranian Oil Company Design and supply NGL base heating and control boards (Ex),107,500,SRM50-2CT
AIOC Design, supply and install trace heating and insulation to pump skids, 75,000,SRF10-2CR,SRM30-2CR
Emerson Process, supply and install trace heating and insulation to instruments,75,000,SRF16-2CR,
PETROFAC UK, supply and install trace heating and insulation to FPSO,75,000,SRF10-2CR,SRM30-2CR
SHELL GAMBIA, supply and install trace heating and insulation to Metering Skids,75,000,SRM50-2CR
BRITISH ENERGY, supply trace heating and insulation to Nuclear Power Plant CO2 Lines,75,000,SRM50-2CR
17
() 156
89783627 77392898 [email protected]