MAXDOAS horizontal (averaging) effects MPI for Chemistry (MPIC), Mainz, Germany T. Wagner, J. Remmers, S. Beirle.  4-azimuth MAX -DOAS measurements in Mainz  Characterisation of the information content using 3D RTM. Master Thesis, Julia Remmers. Comparison of the Telescopes (5°) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: 4-azimuth MAX -DOAS measurements in Mainz

4-azimuth MAX-DOAS measurements in Mainz Characterisation of the information content using 3D RTM

MAXDOAS horizontal (averaging) effects

MPI for Chemistry (MPIC), Mainz, Germany

T. Wagner, J. Remmers, S. Beirle

Master Thesis, Julia Remmers

Page 2: 4-azimuth MAX -DOAS measurements in Mainz

Comparison of the Telescopes (5°)NO2 DSCDs

Page 3: 4-azimuth MAX -DOAS measurements in Mainz

Gradient plots (1)

• Measurement for the horizontal variability• Possibility to detect sources

Page 4: 4-azimuth MAX -DOAS measurements in Mainz

N

S

W E

Gradient plots (2) NO2 DSCDs

Page 5: 4-azimuth MAX -DOAS measurements in Mainz

Gradient plots (3)

Page 6: 4-azimuth MAX -DOAS measurements in Mainz

3D, spherical Monte Carlo RTM

MCARTIM, Tim Deutschmann

- 1D, 2D, 3D Box AMF

Visualisation of a Monte-Carlo radiative transfer simulation (yellow: surface reflection, red: Rayleigh scattering, green: particle scattering)

Page 7: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 500nm, no aerosols

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 1°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 8: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 1°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 9: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, aerosols 1-1km, OD 0.5

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 1°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 10: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 1°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 11: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 2°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 12: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 5°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 13: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 10°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 14: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

10 km

5 km

0 km-200 km 0 km 200 km

MAX-DOASelevation: 30°

horizontal grid: 8 km x 8km vertical grid: 100m

SZA: 70°

Page 15: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

MAX-DOAS

elevation: 1°

Page 16: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

MAX-DOAS

elevation: 1°

Page 17: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 360nm, no aerosols

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

MAX-DOAS

elevation: 1°

Page 18: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 500nm, no aerosols

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

elevation: 1°

Page 19: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 500nm, aerosols: 0-1km, OD 0.1

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

elevation: 1°

Page 20: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 500nm, aerosols: 0-1km, OD 0.2

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

elevation: 1°

Page 21: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 500nm, aerosols: 0-1km, OD 0.3

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

elevation: 1°

Page 22: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 500nm, aerosols: 0-1km, OD 0.5

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

elevation: 1°

Page 23: 4-azimuth MAX -DOAS measurements in Mainz

Box AMF 0-1km, 500nm, aerosols: 0-1km, OD 1

50 km

0 km

-50 km-50 km 0 km 50 km

horizontal grid: 2km x 2km

SCIA: 30 km x 60 km

elevation: 1°

Page 24: 4-azimuth MAX -DOAS measurements in Mainz

Conclusions

• Horizontal gradients can be determined from 4-azimuth MAX-DOAS observations

=> information on location of sources

• 3D-distribution of the sensitivity of MAX-DOAS depends strongly on wavelength and aerosol load

• horizontal area with box-AMF > 1 ranges typically from ~3 km to ~30 km

• spatial resolution of future satellite instruments maches that of MAX-DOAS observations (or is even finer)

Page 25: 4-azimuth MAX -DOAS measurements in Mainz

6/24/09 04:48 6/24/09 09:36 6/24/09 14:24 6/24/09 19:12

Tim e

1E+5

1E+6

1E+7 R

adia

nce

[cou

nts/

sec]

0.0

0.2

0.4

0.6

CI

(rat

io 3

20/4

40)

0.0E+0

1.0E+3

2.0E+3

3.0E+3

O

4 D

SC

D

[1e4

0]

Cabauw, 24.06.2009

Page 26: 4-azimuth MAX -DOAS measurements in Mainz

6/21/09 04:48 6/21/09 09:36 6/21/09 14:24 6/21/09 19:12

Tim e

1E+5

1E+6

1E+7 R

adia

nce

[cou

nts/

sec]

0.0

0.2

0.4

0.6

CI

(rat

io 3

20/4

40)

0.0E+0

1.0E+3

2.0E+3

3.0E+3

O

4 D

SC

D

[1e4

0]

Cabauw, 21.06.2009

Page 27: 4-azimuth MAX -DOAS measurements in Mainz

7/7/09 04:48 7/7/09 09:36 7/7/09 14:24 7/7/09 19:12

Tim e

1E+5

1E+6

1E+7

Rad

ianc

e [c

ount

s/se

c]

0.0

0.2

0.4

0.6

CI

(rat

io 3

20/4

40)

0.0E+0

1.0E+3

2.0E+3

3.0E+3

O

4 D

SC

D

[1e4

0]

Cabauw, 07.07.2009

Page 28: 4-azimuth MAX -DOAS measurements in Mainz
Page 29: 4-azimuth MAX -DOAS measurements in Mainz
Page 30: 4-azimuth MAX -DOAS measurements in Mainz

-1

0

1

2

3

4

4:00 8:00 12:00 16:00Time

O4 D

AM

F

O4_AMFO4_AMF_normO4_diff

O4 DAMFO4 DAMF clear dayDifference

-2

0

2

4

4:00 8:00 12:00 16:00Time

Ra

dia

nce

[arb

itra

ry u

nits

]

-100%

0%

100%

200%

Re

lativ

e d

iffe

ren

ce .

Rad_2Rad_norm_2Rad_ratio

RadianceRadiance clear dayrelative Difference

MODIS, 12 September 9:54MODIS, 12 September 9:54

Page 31: 4-azimuth MAX -DOAS measurements in Mainz

-1

0

1

2

3

4

4:00 8:00 12:00 16:00Time

O4

DA

MF

O4_AMFO4_AMF_normO4_diff

O4 DAMFO4 DAMF clear dayDifference

-2

0

2

4

4:00 8:00 12:00 16:00Time

Ra

dia

nce

[arb

itra

ry u

nits

]

-100%

0%

100%

200%

Re

lativ

e d

iffe

ren

ce .

Rad_2Rad_norm_2Rad_ratio

RadianceRadiance clear dayrelative Difference

MODIS, 09 September 11:01MODIS, 09 September 11:01